Why the study?
How rapid changes in AF ablation platforms translate into longitudinal patterns of technology use and procedural characteristics in routine electrophysiology services was less well described.
Population
2862 AF ablation procedures at a UK tertiary center
Comparison
Radiofrequency ablation vs cryoballoon vs pulsed field ablation over time
Design
Retrospective, procedure-level longitudinal service evaluation
Key result
Over 11 years, AF ablation practice shifted toward newer technologies, accompanied by reductions in median procedure time (205 to 104 min) and fluoroscopy time (32 to 13 min).
Authors
Loading...
Efficiency gains with newer AF ablation technologies may aid workflow and radiation safety; leaves open causal effects on outcomes and generalizability.
Observational (n=2,862)
No
Over an 11-year period at a UK tertiary center, the progressive adoption of newer AF ablation technologies was associated with substantial reductions in procedure duration and radiation exposure.
Antoun et al. (2026) conducted an observational in Atrial Fibrillation (n=2,862). AF ablation technologies (radiofrequency, cryoballoon, pulsed field ablation) was evaluated on Annual technology use, skin-to-skin procedure time, fluoroscopy time, and dose-area product (DAP). Over 11 years, AF ablation practice shifted toward newer technologies, accompanied by reductions in median procedure time (205 to 104 min) and fluoroscopy time (32 to 13 min).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: