Does 3D-TOE provide more reliable assessment of mitral valve leaflet morphology compared to 2D-TOE in patients with severe mitral regurgitation prior to interventional repair?
Cross-Sectional (n=59)
Does 3D-TOE provide more reliable assessment of mitral valve leaflet morphology compared to 2D-TOE in patients with severe mitral regurgitation prior to interventional repair?
Absolute Event Rate: 12.1% vs 10%
p-value: p=< .001
3D-TOE is superior to 2D-TOE for accurate assessment of mitral valve leaflet morphology, preventing erroneous underestimation of posterior leaflet length that could lead to inappropriate exclusion from interventional repair.
3D-TOE may provide superior PML assessment versus 2D-TOE in severe MR; leaves open effects on repair eligibility.
BACKGROUND: Interventional mitral valve (MV) repair of severe symptomatic mitral regurgitation (MR) is a therapeutic option in high-risk surgical or inoperable patients. Assessment of the MV remains a crucial part of pre-interventional screening. Three-dimensional transoesophageal echocardiography (3D-TOE) may compensate for well-known pitfalls that occur in 2D-TOE. PURPOSE: We investigated whether the functional length of the central segments of the posterior and anterior MV leaflets (PML-P2 and AML-A2) is more reliably determined by 3D-TOE full volume datasets (3D-MPR) or orthogonal biplane-imaging (Xplane) when compared to 2D-TOE. METHODS AND RESULTS: Between February 2014 and August 2015, 265 consecutive patients with moderate to severe symptomatic MR were screened. Seventy patients were judged suitable for interventional MV repair by the in-house Heart-Team. Eventually, 59 patients remained for data analysis. Inter-observer variability was lowest in 3D-MPR followed by Xplane (r = 0.92 and 0.90, p < .001 for both) and highest in Mplane (r = 0.82, p < .001). Mean functional PML-P2 lengths were similar in Xplane (12.6 ± 1.7 mm) and 3D-MPR (12.1 ± 2.0 mm), however, significantly different in 2D-TOE (10.0 ± 2.1 mm, p < .001). 2D-TOE underestimated PML-P2 length with a bias of -2.5 mm compared to Xplane and -1.95 mm compared to 3D-MPR. In contrast, functional AML-A2 length was determined similar across all methods. CONCLUSIONS: Our results demonstrate the superiority of 3D-TOE over 2D-TOE for accurate MV assessment in MR, especially for the determination of the functional PML length. Erroneous MV leaflet assessment may result in inadequate therapy restriction if the MV is deemed not suitable for interventional repair.
No takes yet. Share an insight, caveat, or question.
Alfakhouri et al. (2017) conducted a cross-sectional in moderate to severe symptomatic mitral regurgitation (n=59). 3D-TOE (3D-MPR) and Xplane vs. 2D-TOE was evaluated on Mean functional PML-P2 length (p=< .001).