Key result
Orthostatic device usage for 90 minutes showed no significant differences in cardiovascular and biomechanical parameters between spinal cord injury patients and healthy controls.
Why the study?
Spinal cord injuries often cause autonomic changes leading to limited orthostatic positioning, prompting investigation into cardiovascular and biomechanical responses during postural elevation.
Does the use of an orthostatic device for 90 minutes change cardiovascular and biomechanical parameters in patients with spinal cord injury compared to healthy subjects?
Cross-Sectional
Does the use of an orthostatic device for 90 minutes change cardiovascular and biomechanical parameters in patients with spinal cord injury compared to healthy subjects?
Using an orthostatic device for 90 minutes is physiologically well-tolerated in patients with spinal cord injury, showing no significant cardiovascular or biomechanical differences compared to healthy controls.
Answers are grounded in this paper and cite their sources.
Parameters remain stable with device use in SCI; leaves open clinical utility pending larger prospective trials.
Background. Changes in autonomic function are often caused by spinal cord injuries, which lead to limited orthostatic positioning in these patients. Objective. To investigate the cardiovascular and biomechanical parameters during 90 min of postural elevation equipment usage comparing spinal cord injury and healthy subjects. Methods. A device was used that allowed patients with spinal cord injuries to remain in an orthostatic posture for 90 min. During this period, the physiological parameters were measured every 15 min. Cardiovascular parameters (heart rate, oxygen saturation, blood pressure, and autonomic nervous system) and biomechanical parameters of the plantar pressure distribution were evaluated. For blood pressure, heart rate, oxygen saturation, and autonomic nervous system, a two-way analysis of variance was applied. The mixed-effect model was applied to plantar pressure. The significance level was set at p < 0.05 for all statistical analyses. Results. No differences were observed between the groups in systolic blood pressure ( F = 0.07 ), diastolic blood pressure ( F = 0.14 ), heart rate ( F = 0.56 ), and oxygen saturation ( F = 0.23 ) at any of the time intervals throughout the experiment ( p > 0.05 ). No statistical difference was observed in the mean plantar pressure values between the groups ( p = 0.35 ) during the period in which they remained in the orthostatic position. Conclusion. The present study showed the absence of differences between spinal cord injury patients and control participants using the orthostatic device in terms of cardiovascular and biomechanical parameters over 90 min.
No takes yet. Share an insight, caveat, or question.
Oliveira et al. (2022) conducted a cross-sectional in Spinal cord injury. Orthostatic device vs. Healthy subjects was evaluated on Cardiovascular and biomechanical parameters (p=>0.05). Orthostatic device usage for 90 minutes showed no significant differences in cardiovascular and biomechanical parameters between spinal cord injury patients and healthy controls.
Synapse has enriched 10 related papers. Consider them for comparative context: