Answers are grounded in this paper and cite their sources.
Through microstructural observation, phase analysis, and mechanical testing, the effects of four induction heat treatment configurations—single-inductor quenching (HT1), dual-inductor quenching (HT2), single-inductor normalizing plus quenching (HT3), and dual-inductor normalizing plus quenching (HT4)—followed by uniform tempering on HT300 gray cast iron (HT300-GCI) guideways were investigated. All tempered hardened zones consisted of twinned martensite and carbides, though microstructural evolution varied. HT1 retained the highest content of retained austenite, followed by HT2. HT3 promoted coarse martensite, while HT4 exhibited the lowest contents of both carbides and retained austenite. Consequently, HT4 achieved the maximum hardened case depth (5.75 mm) and highest peak hardness (887.3 HV0.2). However, HT1 suffered the most severe wear due to higher retained austenite, undissolved carbides, and lower overall hardness. Conversely, HT2 demonstrated optimal wear resistance, attributed to a unique synergistic toughening effect from a relatively high matrix hardness combined with F-type graphite.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: