The new electromagnetic and mechanical designs of the S-band 1.4 cell photoinjector are discussed. A novel fabrication method is adopted to replace the brazing process with a clamping technique achieving lower breakdown probability. The photoinjector is designed to operate at a 120 MV/m gradient and an optimal injection phase of 70 degrees to improve the extraction field by a factor of 1.9 compared to standard 1.6 cell designs with the same peak field. New geometries and features are implemented to improve beam quality for the demand of high brightness beam applications.