Experimental diagnostics in a hollow-anode vacuum arc device have shown that the repetitive growth and collapse of an anode sheath is responsible for observed tens-of-kV voltage spikes. A dynamic model of device operation based on circuit effects and a time varying quasi-Child-Langmuir sheath is presented. The scaling of the repetition rate with respect to cathode material is discussed. The device is being investigated for use as a current limiter for ~10-MW pulses.
No takes yet. Share an insight, caveat, or question.
Dollinger et al. (1980) studied this question.