Key result
Off-pump implantation of an apicoaortic valved graft in a swine model changed proximal aortic flow from 1508 ± 435 mL/min to -529 ± 241 mL/min (P<0.001) without negatively impacting coronary flow.
Why the study?
Does off-pump implantation of an apicoaortic valved graft maintain coronary flow and hemodynamics in a swine model of severe aortic stenosis?
Does off-pump implantation of an apicoaortic valved graft maintain coronary flow and hemodynamics in a swine model of severe aortic stenosis?
Off-pump implantation of an apicoaortic valved graft is safe and maintains coronary flow and hemodynamics in a swine model of severe aortic stenosis.
Supports preclinical safety of off-pump apicoaortic grafting in severe AS models; leaves open human translation.
OBJECTIVE: : To determine the hemodynamic effect of an off-pump apicoaortic valved graft (AAVG) implantation, we performed a quantitative coronary flow analysis in a swine model of severe aortic stenosis. METHODS: : In 10 swine, cardiac output, coronary flow, right common carotid artery flow, and internal mammary artery flow were measured along with left and right ventricular pressures and aortic and pulmonary artery pressures. A novel AAVG was implanted off-pump on the left ventricular (LV) apex using a specially designed implantation tool and anastomosed to the descending thoracic aorta. Aortic flow was measured proximally and distally of the AAVG-to-descending thoracic aorta anastomosis. After AAVG implantation, epicardial echo confirmed occlusion of the LV outflow tract by a valvuloplasty balloon. Baseline simultaneous measurements of all parameters were repeated after AAVG implantation and intravenous Dobutamine administration. RESULTS: : The AAVG was implanted without any blood loss. After AAVG implantation and LV outflow tract occlusion, the aortic flow proximal to the AAVG-to-descending thoracic aorta anastomosis changed from antegrade (1508 ± 435 mL/min) to retrograde (-529 ± 241 mL/min, P < 0.001). All other measured parameters remained unchanged compared with baseline. After intravenous Dobutamine administration, LV pressure increased from 88 ± 20 to 184 ± 36 mm Hg (+209%, P < 0.0001) and coronary flow increased from 75 ± 34 to 193 ± 90 mL/min (+257%, P = 0.001). CONCLUSIONS: : The off-pump implantation of an AAVG is bloodless, safe, reproducible and has no negative impact on coronary flow and hemodynamics. In addition, to the best of our knowledge, this is the first study where blood flow in all coronary arteries was measured simultaneously during an AAVG implantation.
No takes yet. Share an insight, caveat, or question.
Karapanos et al. (2011) studied Severe aortic stenosis (swine model) (n=10). Off-pump apicoaortic valved graft (AAVG) implantation vs. Baseline was evaluated on Aortic flow proximal to the AAVG-to-descending thoracic aorta anastomosis (p=<0.001). Off-pump implantation of an apicoaortic valved graft in a swine model changed proximal aortic flow from 1508 ± 435 mL/min to -529 ± 241 mL/min (P<0.001) without negatively impacting coronary flow.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: