Key result
Severe prosthesis-patient mismatch occurred in 6.5% of patients undergoing TAV-in-TAVR and was associated with significantly higher 1-year all-cause mortality compared to those with no mismatch (40% vs 9.7%, p=0.016).
Why the study?
Severe prosthesis-patient mismatch is linked to adverse outcomes after TAVR for native stenosis or failed surgical valves, but its impact in TAV-in-TAVR remains unknown.
Does severe prosthesis-patient mismatch impact 1-year mortality and functional status in patients undergoing TAV-in-TAVR?
Observational (n=155)
Yes
Does severe prosthesis-patient mismatch impact 1-year mortality and functional status in patients undergoing TAV-in-TAVR?
Severe prosthesis-patient mismatch occurs in 6.5% of TAV-in-TAVR cases and is associated with significantly increased 1-year all-cause mortality and worse functional status.
Answers are grounded in this paper and cite their sources.
Severe PPM after TAV-in-TAVR signals higher 1-year mortality risk; leaves open optimal valve selection strategies for degenerated THVs.
Background A severe prosthesis-patient mismatch (PPM) is associated with adverse outcomes following transcatheter aortic valve replacement (TAVR) for de novo aortic stenosis or a failed surgical bioprosthesis. The impact of severe PPM in patients undergoing TAV-in-TAVR is unknown. Aim We sought to investigate the incidence and 1-year outcomes of different grades of PPM in patients undergoing TAV-in-TAVR. Materials and methods The TRANSIT-PPM is an international registry, including cases of degenerated TAVR treated with a second TAVR. PPM severity, as well as in-hospital, 30-day, and 1-year outcomes were defined according to the Valve Academic Research Consortium-3 (VARC-3) criteria. Results Among 28 centers, 155 patients were included. Severe PPM was found in 6.5% of patients, whereas moderate PPM was found in 14.2% of patients. The rate of severe PPM was higher in patients who underwent TAV-in-TAVR with a second supra-annular self-expanding (S-SE) TAVR (10%, p = 0.04). Specifically, the rate of severe PPM was significantly higher among cases of a SE TAVR implanted into a balloon-expandable (BE) device (19%, p = 0.003). At 1-year follow-up, the rate of all-cause mortality, and the rate of patients in the New York Heart Association (NYHA) class III/IV were significantly higher in the cohort of patients with severe PPM ( p = 0.016 and p = 0.0001, respectively). Almost all the patients with a severe PPM after the first TAVR had a failed < 23 mm BE transcatheter heart valve (THV): the treatment with an S-SE resolved the severe PPM in the majority of the cases. Conclusion After TAV-in-TAVR, in a fifth of the cases, a moderate or severe PPM occurred. A severe PPM is associated with an increased 1-year all-cause mortality. Clinical trial registration [ https://clinicaltrials.gov ], identifier [NCT04500964].
No takes yet. Share an insight, caveat, or question.
Testa et al. (2022) conducted an observational in Degenerated transcatheter aortic valves (n=155). Severe prosthesis-patient mismatch vs. Moderate or no prosthesis-patient mismatch was evaluated on 1-year all-cause mortality (p=0.016). Severe prosthesis-patient mismatch occurred in 6.5% of patients undergoing TAV-in-TAVR and was associated with significantly higher 1-year all-cause mortality compared to those with no mismatch (40% vs 9.7%, p=0.016).