Key result
Next-generation Micra VR2 extends projected median device longevity by ~4.4 years over first-generation Micra.
Why the study?
The impact of battery and electronics enhancements on the projected device longevity of next-generation Micra VR2 and AV2 leadless pacemakers compared with first-generation Micra VR and AV devices needed to be assessed.
Do battery and electronics enhancements in next-generation Micra VR2 and AV2 leadless pacemakers improve projected device longevity and reduce lifetime device replacements compared to first-generation Micra VR and AV devices?
Observational (n=1,643)
Yes
Do battery and electronics enhancements in next-generation Micra VR2 and AV2 leadless pacemakers improve projected device longevity and reduce lifetime device replacements compared to first-generation Micra VR and AV devices?
Answers are grounded in this paper and cite their sources.
Battery and electronic optimizations in next-generation Micra VR2 and AV2 leadless pacemakers are projected to extend median device longevity to 16.7 and 15.6 years respectively, allowing 80% to 91% of patients to be served by a single device for life.
BACKGROUND: Leadless ventricular pacemakers have been developed for single chamber VVIR and AV synchronous pacing applications. AIM: To assess the device longevity impact of battery/electronics enhancements of next-generation Micra leadless pacemakers, Micra VR2 and AV2, compared to Micra VR and AV. METHODS: Real-world pacing data gathered from the Micra IDE study, Medtronic's CareLink database, and historical pacemaker patient survival data from Medtronic's Device Registry were used to project device longevity and estimate the proportion of patients requiring lifetime device replacements. RESULTS: Based on data from 644 patients, the median projected longevity of Micra VR was 12.3 years and Micra VR2 was 16.7 years, with 91% of patients requiring a single VR2 device over their lifetime. Based on data from 999 patients, the median projected longevity of Micra AV was 10.8 years and Micra AV2 was 15.6 years, with 80% of patients requiring one AV2 device. The longevity improvements with Micra VR2 projected 8 fewer device replacements would be required across 100 patients. Similarly, 15 devices would be avoided when considering Micra AV versus AV2. CONCLUSIONS: Modeling of the Micra leadless pacemakers projected meaningful improvements in device longevity and an increase in the number of patients served with a single device.
No takes yet. Share an insight, caveat, or question.
Leal et al. (2025) conducted an observational in Bradyarrhythmias and atrioventricular block requiring leadless ventricular or AV synchronous pacing (n=1,643). Next-generation Micra leadless pacemakers (Micra VR2 and Micra AV2) vs. First-generation Micra leadless pacemakers (Micra VR and Micra AV) was evaluated on Median projected device longevity to Recommended Replacement Time (RRT) in years (Micra VR2 vs Micra VR). Micra VR2 and AV2 projected longer median device longevity than Micra VR and Micra AV, allowing 91% of VR2 and 80% of AV2 patients to need only one device.