Answers are grounded in this paper and cite their sources.
OBJECTIVES: The primary purposes of this study were to measure axial rotation during supine cervical spinal manipulative therapy (cSMT) and to record recipients' and doctors' perceptions of rotational magnitudes. METHODS: Experienced doctors of chiropractic (DCs) provided supine cSMT and acted as recipients of cSMT. Participants who received SMT wore inertial measurement units attached to the forehead and sternum for motion capture. Afterward, recipients and DCs completed questionnaires asking about their perceptions of motion. Data were analyzed for magnitudes of axial rotation at peak thrust and correlations with patient and doctor perceptions. Secondary analyses included angular velocity, angular acceleration, and other kinematic variables. RESULTS: (2456.6), respectively. We found no correlation between perceptions and velocity or acceleration; doctors' perceptions had an inverse correlation with measurements. CONCLUSION: On average, we found rotation during supine cSMT to be 32°. Both DCs and SMT recipients overestimated rotation compared with actual measurements. These factors should be considered in discussions of rotation and SMT.
No takes yet. Share an insight, caveat, or question.
Russell et al. (2022) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: