Answers are grounded in this paper and cite their sources.
The stability of high-power AlGaN/GaN HEMTs under DC and RF stresses was evaluated. For 50 hours of DC stresses, 100 µm devices exhibited ∼3% full-channel drain current degradation within the first few minutes and another ∼1% current loss during the rest of the stress period. In response to the RF stresses under pulsed conditions at 2.8 GHz, the output power of 1.5 mm devices degraded by ∼13% after 108 hours of stress. Current DLTS measurements revealed the creation of a 0.4 eV trap from the stressed and aged devices.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2004) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: