Key result
Doppler ultrasonography demonstrated that maximum systolic velocity in the fetal heart was highest in the first trimester and lower in the second and third trimesters.
Why the study?
The study was conducted to determine blood flow velocity parameters in the fetal heart and aorta in goats using Doppler ultrasonography.
Observational (n=24)
Doppler ultrasonography can effectively monitor fetal blood flow changes across different stages of pregnancy in goats.
Answers are grounded in this paper and cite their sources.
Provides initial caprine fetal cardiac Doppler references; leaves open validation before clinical veterinary adoption.
The aim of the present study was to determine the parameters characterising the blood flow velocity in the fetal heart and aorta in goats by Doppler ultrasonography. Twenty-four Bulgarian White milk goats, aged 4-6 years, weighing 45-51 kg were used in the study. Doppler ultrasound measurements of the blood flow velocity in fetal heart were done at the end of first, second and third trimesters of pregnancy, and in the fetal aorta - at the end of the second and third trimesters of pregnancy. Ultrasound investigations were carried out by transabdominal approach with linear and convex transducers, with frequency 8.0 MHz. Blood flow parameters that included maximum and minimum systolic velocity, end-diastolic velocity, pulsatility index, resistance index and systolic/diastolic ratio were measured by spectral Doppler ultrasonography. The results showed that the highest maximum systolic velocity in the fetal heart was observed at the end of the first pregnancy trimester. Statistically significantly (p < 0.05) lower values of this parameter were registered in the second and third pregnancy trimesters. A similar tendency was observed for minimum systolic velocity, end-diastolic velocity and systolic/diastolic ratio. The pulsatility index and resistance index had similar values for the three studied periods. Examination of the fetal aorta showed statistically significant differences (p < 0.05) of minimum systolic velocity, end-diastolic velocity, pulsatility and resistance index in the third, compared with the second trimester of pregnancy. The analysis of the results suggested that Doppler ultrasonography can be used to monitor fetal blood flow changes during the various stages of pregnancy.
No takes yet. Share an insight, caveat, or question.
Fasulkov et al. (2021) conducted an observational in Pregnancy (n=24). Pregnancy trimester vs. Between trimesters was evaluated on Maximum systolic velocity in the fetal heart (p=< 0.05). Doppler ultrasonography demonstrated that maximum systolic velocity in the fetal heart was highest in the first trimester and lower in the second and third trimesters.
Synapse has enriched 10 related papers. Consider them for comparative context: