A sensor for simultaneous and continuous measurements of water vapor density, temperature, and velocity has been developed based on absorption techniques using room temperature diode lasers (InGaAsP) operating at 1.31 µm. Laboratory calibrations of density and temperature were acquired in a variable temperature absorption cell and on a H 2‐air e at e ame burner from 500 to 2200 K. Laboratory determinations showed absolute accuracies of 5% in temperature and 10% in molecular density for a 0.3-Hz bandwidth. An optical system was developed for integratingthesensortoamodelscramjetcombustorattheU.S.AirForceResearchLaboratory,Wright ‐Patterson Air Force Base. Preliminary measurements in the Mach 2.1 e owe eld at expanded temperatures of 540, 650, and 740 K across an 18-cm pathlength resulted in temperature measurements that agreed with theoretical predictions to within 7‐11%. Density measurements agreed with predictions to within 17 ‐56%. Velocity measurement precision was compromised by beam steering effects, although results in reasonable agreement with predictions were observed at the lowest enthalpy condition.