Key result
A newly developed high-resolution SPECT imaging system accurately quantified myocardial infarction area in rats, with results comparable to histologic assessment.
Why the study?
Does high-resolution SPECT imaging accurately quantify myocardial infarction area compared to histology in a rat model?
Does high-resolution SPECT imaging accurately quantify myocardial infarction area compared to histology in a rat model?
An adapted, low-cost high-resolution SPECT imaging system accurately quantifies myocardial infarction area in rats, showing excellent correlation with histological fibrosis.
Answers are grounded in this paper and cite their sources.
Does not inform clinical MI imaging; leaves open further validation of high-resolution SPECT in rodent models.
BACKGROUND: Imaging techniques enable in vivo sequential assessment of the morphology and function of animal organs in experimental models. We developed a device for high-resolution single photon emission computed tomography (SPECT) imaging based on an adapted pinhole collimator. OBJECTIVE: To determine the accuracy of this system for quantification of myocardial infarct area in rats. METHODS: Thirteen male Wistar rats (250 g) underwent experimental myocardial infarction by occlusion of the left coronary artery. After 4 weeks, SPECT images were acquired 1.5 hours after intravenous injection of 555 MBq o f 99mTc-Sestamibi. The tomographic reconstruction was performed by using specially developed software based on the Maximum Likelihood algorithm. The analysis of the data included the correlation between the area of perfusion defects detected by scintigraphy and extent of myocardial fibrosis assessed by histology. RESULTS: The images showed a high target organ/background ratio with adequate visualization of the left ventricular walls and cavity. All animals presenting infarction areas were correctly identified by the perfusion images. There was no difference of the infarct area as measured by SPECT (21.1 ± 21.2%) and by histology (21.7 ± 22.0%; p=0.45). There was a strong correlation between individual values of the area of infarction measured by these two methods. CONCLUSION: The developed system presented adequate spatial resolution and high accuracy for the detection and quantification of myocardial infarction areas, consisting in a low cost and versatile option for high-resolution SPECT imaging of small rodents.
No takes yet. Share an insight, caveat, or question.
Oliveira et al. (2013) studied Experimental myocardial infarction (n=15). High-resolution SPECT imaging vs. Histology was evaluated on Myocardial infarct area (% of left ventricular surface) (p=0.45). A newly developed high-resolution SPECT imaging system accurately quantified myocardial infarction area in rats, with results comparable to histologic assessment.
Synapse has enriched 10 related papers. Consider them for comparative context: