This is the authors' abstract. We don't add key points for this paper.
Introduction The acute toxicity of cyanide along with its continue industrial use makes this substance of environmental concern [1 Ma J, Dasgupta P. Recent developments in cyanide detection: a review. Anal Chim Acta. 2010;673(2):117–125.[Crossref], [PubMed], [Web of Science ®] , [Google Scholar]]. Titration, spectrophotometry and ISE are the standard detection methods. However, they are complex and need sample pre-treatment [2 Mak K, Yanase H, Renneberg R. Cyanide fishing and cyanide detection in coral reef fish using chemical test and biosensors. Biosens Bioelectron. 2005;20(12):2581–2593.[Crossref], [PubMed], [Web of Science ®] , [Google Scholar]]. To overcome these, another approach is using biosensors. To this end, we developed a disposable inhibition-based biosensor with a multi-heme nitrite reductase (ccNiR) coupled to graphite leads.Materials and methods Electrochemical measurements were carried out in a conventional electrochemical cell, composed by a three-electrode system. The reference was an Ag/AgCl electrode, and the counter electrode was a Pt wire. The working electrode (WE) was in-house made using a graphite lead with the ccNiR (from bacteria D. desulfuricans ATCC 27774; stored in 0.05 M phosphate buffer, pH 7.6) immobilised by drop cast at the WE surface. The electrochemical technique used was square wave voltammetry. Electrochemical cells contained 0.1 M KCl in 0.1 M Tris–HCl buffer (pH 7.6) as supporting electrolyte. Dissolved oxygen was removed by a biochemical system (GOx, catalase and glucose).Discussion and conclusions In Figure 1 we can observe the decrease in catalytic activity due to the presence of cyanide. The biosensor dynamic range comprises the maximum value imposed by the European Union, 1.92 µM (98/83/EC directive), which does not happen with other cyanide biosensors [3 Shan D, Mousty C, Cosnier S. Subnanomolar cyanide detection at polyphenol oxidase/clay biosensors. Anal Chem. 2004;76(1):178–183.[Crossref], [PubMed], [Web of Science ®] , [Google Scholar]]. Furthermore, a graphite lead cost 0.35€ and each of them can be split, allowing a very low-cost biosensor. Given that enzyme inhibition is reversible [4 Gwyer J, Richardson D, Butt J. Resolving complexity in the interaction of redox enzymes and their inhibitors: Contrasting mechanisms for the inhibition of cytochrome c nitrite reductase revealed by protein film voltammetry. Biochemistry. 2004;43(47):15086–15094.[Crossref], [PubMed], [Web of Science ®] , [Google Scholar]], the sensor can be used more than one time, if we optimise the enzyme immobilisation method.Inhibition-based biosensor for cyanide detection – a preliminary studyAll authorsAna R. Coelho, Tiago Monteiro, Ana S. Viana & M. Gabriela Almeidahttps://doi.org/10.1080/07853890.2021.1896915Published online:28 September 2021Figure 1. (I) Square wave voltammograms with baseline correction of one of the WE used in the study. Enzymatic inhibition by cyanide among 1–80 µM in the presence of 40 µM of nitrite. (II) Calibration curve (y = 0.200x + 0.135; R2 = 0.995) for CN- quantification, with the dynamic range 1 to 40 µM. Results are expressed as triplicate average with the corresponding standard deviation.Display full sizeFigure 1. (I) Square wave voltammograms with baseline correction of one of the WE used in the study. Enzymatic inhibition by cyanide among 1–80 µM in the presence of 40 µM of nitrite. (II) Calibration curve (y = 0.200x + 0.135; R2 = 0.995) for CN- quantification, with the dynamic range 1 to 40 µM. Results are expressed as triplicate average with the corresponding standard deviation.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Coelho et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: