Key result
Single-chamber ICD was not associated with increased risk of death or heart failure admission compared to dual-chamber ICD, but increased inappropriate therapy in ischemic heart disease patients.
Why the study?
Does a single-chamber ICD compared to a dual-chamber ICD improve clinical outcomes in patients requiring primary prevention of sudden cardiac death?
Cohort (n=1,125)
Yes
Does a single-chamber ICD compared to a dual-chamber ICD improve clinical outcomes in patients requiring primary prevention of sudden cardiac death?
In a national registry cohort, single-chamber ICDs showed similar rates of mortality and heart failure admissions compared to dual-chamber ICDs for primary prevention, but may be associated with more inappropriate therapy in patients with ischemic heart disease.
Similar outcomes with single- versus dual-chamber ICDs in registry; leaves open optimal device selection pending randomized data.
OBJECTIVE: To compare the clinical outcomes of a single- versus dual-chamber ICD for primary prevention of sudden cardiac death in a large, national ICD registry. METHODS: Data were collected from the prospective Israeli ICD Registry. Baseline characteristics and clinical outcomes including mortality, admissions for heart failure (HF), and ICD therapy were compared between the two groups. RESULTS: A total of 1,125 subjects, 37% with a single-chamber and 63% with a dual-chamber ICD, constructed the baseline cohort. Approximately 80% had ischemic heart disease (IHD). Mean follow-up was 22 months, mean ejection fraction was 30%, and mean QRS width was 103 milliseconds in both groups. During follow-up, there were no significant differences in the rate of mortality, admissions for HF, appropriate or inappropriate therapy, or in time to any of the clinical outcomes. Using multivariate analysis, single-chamber ICD was not associated with increased risk of death or admission for HF. In a subgroup of patients with IHD, single-chamber ICD was associated with a higher rate of inappropriate therapy. CONCLUSIONS: In this large retrospective population-based cohort, dual-chamber ICD showed no benefit in reducing the incidence of death or HF admissions, whereas in a subgroup of patients with IHD, single-chamber ICD was associated with increased inappropriate therapy. Further prospective studies are necessary to assess the benefit of dual-chamber ICD in reducing the rate of inappropriate therapy.
No takes yet. Share an insight, caveat, or question.
Konstantino et al. (2016) conducted a cohort in primary prevention of sudden cardiac death (n=1,125). Single-chamber ICD vs. Dual-chamber ICD was evaluated on mortality, admissions for heart failure, and ICD therapy. Single-chamber ICD was not associated with increased risk of death or heart failure admission compared to dual-chamber ICD, but increased inappropriate therapy in ischemic heart disease patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: