STATEMENT OF THE PROBLEM: The complete removal of filling material is an important step to regain access to the entire canal and facilitate the disinfection of the root canal system. Rotary nickel-titanium (NiTi) instruments systems have been proposed as an effective removal technique for root canal retreatment. PURPOSE: The aim of this study was to evaluate the efficacy of Neolix rotary system and ProTaper Universal retreatment system in the removal of gutta-percha combined with two different sealers. MATERIALS AND METHOD: < 0.05). Post hoc Tukey test showed that there is significantly higher residual filling material in the group filled with gutta-percha and Sure-Seal Root sealer and retreated by Neoniti rotary system compared with other groups in both coronal and middle third of the canal. CONCLUSION: The Neoniti rotary system was as effective as ProTaper Universal retreatment system in retreatment of gutta-percha and AH-26 sealer but was significantly less effective in groups obturated with Sure-Seal Root sealer.