This paper investigated a room temperature resistive ammonia gas sensor based on a conductive polymer and N-doped graphene quantum dots (N-GQDs) dopant made on a transparent substrate with electrodes. The sensor fabricated with conductive polymer showed a good sensing response that increases considerably with the addition of N-GQDs. The sensing response of the poly(3,4-ethylenedioxythiophene)-poly(styrenesulfonate) (PEDOT-PSS) to NH3 increased from 30.13% to 212.32% at 1500 ppm with the addition of 50 wt% N-GQDs. The response time of the N-GQDs doped sensor decreased to 6.8 min when compared with the sensor without N-GQDs and the stability of the sensor having combined N-GQDs and PEDOT-PSS was higher than that of the PEDOT-PSS sensor. Meanwhile, the structure and morphology of the sensing film are characterized by Fourier transform infrared spectroscopy and field emissions scanning electron microscopy.
No takes yet. Share an insight, caveat, or question.
Hakimi et al. (2016) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: