Key result
Chronic occupational exposure to sevoflurane in anesthesiologists is associated with adverse effects on liver and kidney function, and can be monitored using urinary sevoflurane and hexafluoroisopropanol.
Why the study?
Daily occupational exposure to sevoflurane presents potential hepatotoxic, nephrotoxic, and neurotoxic hazards for anesthetists, prompting a literature review on biomonitoring.
What are the health effects of chronic sevoflurane exposure in anaesthetists and how can it be biomonitored?
Systematic Review (n=5)
What are the health effects of chronic sevoflurane exposure in anaesthetists and how can it be biomonitored?
Chronic exposure to sevoflurane poses potential hepatotoxic and nephrotoxic risks to anesthesiologists, highlighting the need for environmental and biological monitoring.
ABSTRACTSevoflurane is used by anesthetists for the induction and maintenance of general anesthesia. This causes the anesthetist to get daily exposures. This will be a potential hazard for exposed operating room personnel, especially anesthetists. The adverse health effects of sevoflurane as hepatotoxic, nephrotoxic and neurotoxic in the human body can be a risk for anaesthetists. Biological monitoring can be done by measuring the levels of sevoflurane and its metabolites or by looking at biomarkers for their effects on health effects. The aim of this study was to seek a literature review on the biomonitoring of sevoflurane exposure in anaesthetists. We searched the literature review using the PRISMA method in PubMed and Google scholar using the following keywords "occupational disease" "chronic effects" "anaesthetist" "sevoflurane exposure" "inorganic fluoride" "biomarkers" previously using the term MeSH and combined with Boolen "OR" and AND". We obtain 75 articles taken from the database, excluded 35 articles, and selected 5 articles. The results of the review articles showed that there were health effects, especially on liver and kidney function in chronic exposure. Biological monitoring can be undertaken by detecting sevoflurane and its metabolites in the urine during work and function of the liver and kidneys. The evidence for biological monitoring as surveillance in anaesthesiologists remain inconsistent due to limited studies. We recommend to measure sevoflurane in ambient air using a hierarchy of controls, such as elimination, replacement, engineering, administrative and personal protective equipment. We need to undertaken environmental and biological monitoring in order to acquire a safe and healthy work environment.
No takes yet. Share an insight, caveat, or question.
Ratsmita et al. (2021) conducted a systematic review in Occupational exposure to sevoflurane (n=5). Sevoflurane exposure vs. Unexposed personnel was evaluated on Adverse health effects (liver and kidney function) and biological monitoring markers. Chronic occupational exposure to sevoflurane in anesthesiologists is associated with adverse effects on liver and kidney function, and can be monitored using urinary sevoflurane and hexafluoroisopropanol.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: