Key result
Speckle-tracking LV GLS strongly correlates with invasive LV max dp/dt in children.
Why the study?
Does vendor-independent speckle tracking echocardiography correlate with invasive catheter-derived measurements of cardiac function in children?
Observational (n=28)
Single-blind
Does vendor-independent speckle tracking echocardiography correlate with invasive catheter-derived measurements of cardiac function in children?
Effect estimate: R=-0.83
p-value: p=0.001
Vendor-independent speckle tracking echocardiography, particularly LV global longitudinal strain, correlates strongly with invasive catheter-derived measures of cardiac function in children.
LV speckle tracking strain correlates with invasive dp/dt in children; extends adult data but leaves open noninvasive replacement of catheterization.
BACKGROUND: Adult studies demonstrate that echocardiographic measurements of cardiac function using speckle tracking correlate with invasive measurements, but such data in the pediatric population are sparse. Our aim was to compare speckle-derived measures of cardiac function to measurements routinely obtained by cardiac catheterization in children. METHODS: Echocardiograms were performed on the day of cardiac catheterization. Using Tomtec 2D Cardiac Performance Analysis, longitudinal strain (LS), longitudinal strain rate (LSR), early diastolic LSR, and ejection fraction (EF) for the right and left ventricle (RV and LV) were calculated via speckle tracking. Global LS and LSR were calculated for the LV. These results were compared to cardiac index, maximum ventricular dp/dt (max dp/dt), ventricular end-diastolic pressure (EDP), and pulmonary capillary wedge pressure (PCWP) obtained by fluid-filled catheters. A blinded observer performed all echo measurements. RESULTS: Fifty studies were performed on 28 patients ages 4 months to 20 years old. Their diagnoses included cardiac transplant (48 studies), repaired AV septal defect (1), and dilated cardiomyopathy (1). RVEDP ranged from 2 to 22 mm Hg (median=6) and PCWP ranged from 6 to 32 mmHg (median 10). LV global LS and LV 2-chamber LSR by speckle-tracking negatively correlated with LV max dp/dt (LV global LS R=-.83, P=.001; LV 2-chamber LSR R=-.69, P=.009). RV LS weakly correlated with max dp/dt (R=.363, P=.002). Early diastolic strain rate did not correlate with EDP in either ventricle. CONCLUSION: Speckle-derived measurements of function in the LV have stronger correlation than the RV to catheter-derived measures. LV global LS has the strongest correlation with invasive function measures in children.
No takes yet. Share an insight, caveat, or question.
Goudar et al. (2016) conducted an observational in Pediatric patients undergoing cardiac catheterization (n=28). Speckle tracking echocardiography vs. Cardiac catheterization was evaluated on Correlation between LV global longitudinal strain and LV max dp/dt (R=-0.83, p=0.001). Speckle-tracking echocardiography measurements of LV global longitudinal strain strongly correlated with invasive catheter-derived LV max dp/dt in children (R=-0.83, P=0.001).