Answers are grounded in this paper and cite their sources.
I read with interest the recent paper by Rizzo et al.1, measuring placental vascularization with three-dimensional power Doppler using Virtual Organ Computer-aided AnaLysis (VOCAL) software. Unfortunately, the development of ultrasound machines with the capacity to generate impressive images and numbers does not necessarily give those numbers meaning. Power Doppler measures the amplitude of scattering of ultrasound waves, which is influenced by a large number of factors (e.g. machine settings, gain, filter, beam path). Numerical values derived from power Doppler relating to ‘perfusion’ or ‘flow’ are unitless outside of the examination in question. It is for this reason that numerous articles, including an Opinion2, published in this Journal have described clearly the need for internal standardization (within an image) in order to make comparisons between derived power Doppler indices from that image and those from other images3-7. The values derived from VOCAL are not standardized. This may be acceptable for gynecological imaging, in which the proximity of the ovaries and endometrium to the transvaginal ultrasound probe almost eliminates the beam path8, 9, but it is not acceptable for obstetric ultrasound, including that of the placenta. When standardized, power Doppler measurement produces an index known as the ‘fractional moving blood volume’ that has been shown to correlate well with true tissue perfusion5. The exact technique for this is a matter for scientific discussion, specifically with respect to whether the two-stage method (using the cumulative power distribution function) originally published by Rubin et al.3 is necessary, or whether differing fetal rheology obviates this, requiring only standardization against the maximum value from a single large vessel4. A recent publication in this Journal suggested that the two-stage and maximum large vessel value techniques may in fact generate the same standardization value, and further investigation is required10. The use of identical machine settings for different patients is insufficient to allow for the differing beam path between studies, which is related largely to attenuation and the composition and depth of the intervening tissues, even with purely anterior placentae. Rizzo et al.1 do not state the position of the placentae in their subjects. A posterior placenta may result in a significantly longer beam path than does an anterior one, so power Doppler imaging using pre-set instrument settings would naturally show less ‘flow’ using derived VOCAL indices. The broad (85°) volume angle used may include the entire placenta at this gestational age, but it is disappointing that they only looked at 12 sections of the placenta, reducing the volumetric flow analysis advantage of 3D imaging. The data presented cannot be used to state a normal range or to define an alteration with gestational age. It would be interesting to see whether appropriate standardization techniques would narrow the wide ranges that Rizzo et al.1 obtained for vascularization, flow and vascularization flow indices plotted against crown–rump length, and also reduce the not insignificant intraobserver and interobserver coefficients of variation for these measurements (< 12% and < 14.5%). I would warn against further unstandardized research in this area, direct readers to the elegant standardized studies currently being performed by Hernandez-Andrade et al.10, and look forward to further papers exploring this exciting area. A. W.
No takes yet. Share an insight, caveat, or question.
Alec Welsh (2007) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: