Answers are grounded in this paper and cite their sources.
Experimental study demonstrates focal spot intensity contrast reduction in a high-power ultraviolet beam, indicating safe operation margins for fusion laser systems.
We report an experimental demonstration of polarization smoothing by using a specially cut KDP plate in the convergent ultraviolet (351 nm wavelength) section of a high-power laser system. A 410 mm×410 mm×10 mm sized KDP plate placed after the final focus lens successfully reduced the focal spot intensity contrast to 75.6%, which is in good agreement with the theoretical expectation. In our experiment, no obvious transverse stimulated scattering was observed with the maximum 351 nm laser energy of 4032 J/3 ns, thus indicating the operation safety margin of our laser system.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2015) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: