Key result
Novel ECG-VCG combination technique detects MI with ~95% accuracy.
Why the study?
Does a novel ECG-VCG combination technique accurately identify and localize myocardial infarction compared to healthy reference subjects?
Observational (n=147)
Does a novel ECG-VCG combination technique accurately identify and localize myocardial infarction compared to healthy reference subjects?
A novel multivariable technique combining ECG and VCG indexes demonstrates high accuracy in identifying myocardial infarction and localizing the infarcted area.
Answers are grounded in this paper and cite their sources.
Novel ECG-VCG fusion may enhance MI detection in case-control data; hypothesis-generating and leaves clinical adoption open pending prospective trials.
BACKGROUND: The largest morbidity and mortality group worldwide continues to be that suffering Myocardial Infarction (MI). The use of vectorcardiography (VCG) and electrocardiography (ECG) has improved the diagnosis and characterization of this cardiac condition. OBJECTIVES: Herein, we applied a novel ECG-VCG combination technique to identifying 95 patients with MI and to differentiating them from 52 healthy reference subjects. Subsequently, and with a similar method, the location of the infarcted area permitted patient classification. METHODS: We analyzed five depolarization and four repolarization indexes, say: a) volume; b) planar area; c) QRS loop perimeter; d) QRS vector difference; e - g) Area under the QRS complex, ST segment and T-wave in the (X, Y, Z) leads; h) ST-T Vector Magnitude Difference; i) T-wave Vector Magnitude Difference; and j) the spatial angle between the QRS complex and the T-wave. For classification, patients were divided into two groups according to the infarcted area, that is, anterior or inferior sectors (MI-ant and MI-inf, respectively). RESULTS: Our results indicate that several ECG and VCG parameters show significant differences (p-value<0.05) between Healthy and MI subjects, and between MI-ant and MI-inf. Moreover, combining five parameters, it was possible to classify the MI and healthy subjects with a sensitivity = 95.8%, a specificity = 94.2%, and an accuracy = 95.2%, after applying a linear discriminant classifier method. Similarly, combining eight indexes, we could separate out the MI patients in MI-ant vs MI-inf with a sensitivity = 89.8%, 84.8%, respectively, and an accuracy = 89.8%. CONCLUSIONS: The new multivariable MI patient identification and localization technique, based on ECG and VCG combination indexes, offered excellent performance to differentiating populations with MI from healthy subjects. Furthermore, this technique might be applicable to estimating the infarcted area localization. In addition, the proposed method would be an alternative diagnostic technique in the emergency room.
No takes yet. Share an insight, caveat, or question.
Arini et al. (2016) conducted an observational in Myocardial Infarction (n=147). ECG-VCG combination technique vs. Healthy reference subjects was evaluated on Classification of MI and healthy subjects (Sensitivity 95.8%, Specificity 94.2%, Accuracy 95.2%, p=<0.05). A novel ECG-VCG combination technique classified myocardial infarction patients versus healthy subjects with 95.8% sensitivity, 94.2% specificity, and 95.2% accuracy.