Key result
Accounting for voltage-clamp artefacts improves electrophysiology model predictions using ~66% fewer parameters.
Why the study?
Whole-cell patch-clamp recordings of hERG1a (Kv11.1) channels exhibit substantial cell-to-cell variability, but whether this variability originates from true biological differences in ion channel kinetics or from experimental measurement artefacts had not been identified.
Does accounting for voltage-clamp experimental artefacts with an identical ion channel kinetics model explain cell-to-cell recording variability better than assuming cell-specific ion channel kinetics in CHO cells expressing hERG1a?
Does accounting for voltage-clamp experimental artefacts with an identical ion channel kinetics model explain cell-to-cell recording variability better than assuming cell-specific ion channel kinetics in CHO cells expressing hERG1a?
Demonstrates that apparent cell-to-cell variability in high-throughput patch-clamp hERG ion channel recordings is predominantly driven by experimental artefacts rather than intrinsic biological variation in channel kinetics, enabling post-processing correction and more reliable cardiac action potential modelling.
Answers are grounded in this paper and cite their sources.
Artefact correction with shared kinetics may refine hERG assay reliability; leaves open validation in native human cardiomyocytes.
Mathematical models of ion channels, which constitute indispensable components of action potential models, are commonly constructed by fitting to whole-cell patch-clamp data. In a previous study, we fitted cell-specific models to hERG1a (Kv11.1) recordings simultaneously measured using an automated high-throughput system, and studied cell-cell variability by inspecting the resulting model parameters. However, the origin of the observed variability was not identified. Here, we study the source of variability by constructing a model that describes not just ion current dynamics, but the entire voltage-clamp experiment. The experimental artefact components of the model include: series resistance, membrane and pipette capacitance, voltage offsets, imperfect compensations made by the amplifier for these phenomena, and leak current. In this model, variability in the observations can be explained by either cell properties, measurement artefacts, or both. Remarkably, by assuming that variability arises exclusively from measurement artefacts, it is possible to explain a larger amount of the observed variability than when assuming cell-specific ion current kinetics. This assumption also leads to a smaller number of model parameters. This result suggests that most of the observed variability in patch-clamp data measured under the same conditions is caused by experimental artefacts, and hence can be compensated for in post-processing by using our model for the patch-clamp experiment. This study has implications for the question of the extent to which cell-cell variability in ion channel kinetics exists, and opens up routes for better correction of artefacts in patch-clamp data. This article is part of the theme issue 'Uncertainty quantification in cardiac and cardiovascular modelling and simulation'.
No takes yet. Share an insight, caveat, or question.
Lei et al. (2020) studied hERG1a (Kv11.1) ion current recordings in Chinese hamster ovary (CHO) cells (n=124). Identical kinetics mathematical model accounting for voltage-clamp experimental artefacts (Hypothesis 2) vs. Independent cell-specific kinetics mathematical model assuming ideal voltage-clamp without artefacts (Hypothesis 1) was evaluated on Predictive accuracy on independent validation voltage-clamp protocols quantified by relative root mean square error (RRMSE) and model degrees of freedom. Modelling voltage-clamp artefacts with identical channel kinetics across 124 cells improved validation predictions while using 736 fewer parameters (380 vs 1116) than cell-specific kinetics models.
Synapse has enriched 10 related papers. Consider them for comparative context: