Answers are grounded in this paper and cite their sources.
Background Off-pump bidirectional Glenn (BDG) operation can be associated with elevation of superior vena cava (SVC) pressure that may lead to neurological damage.Aim Off-pump BDG operation was done using either a veno-atrial shunt or external shunt to decompress SVC during clamping.Patients and methods A prospective, randomized comparative study in a single tertiary care cardiac center where 30 patients with functional single ventricle underwent off-pump BDG. Group I with a veno-atrial shunt (internal) and group E with an external shunt.Measurements and main results There was no early hospital mortality. The mean SVC pressure during clamping was 40.4±3.4 mmHg before and 28.5±3.8 mmHg after shunt opening in group I and 37.6±4.5 mmHg before and 26.4±2.1 mmHg after shunt opening in group E. The mean clamp time was 19.8±3.5 min in group I and 16.9±4.4 min in group E. The transcranial pressure gradient was 58.1±6.89 mmHg in group I, while 54.86±9.1 mmHg in group E. There were no major neurological complications apart from treatable convulsions in one (3%) case in group I and delayed recovery in one (3%) case in group E.Conclusions Off-pump BDG can be safely performed with either external or internal shunt avoiding cardiopulmonary bypass complications.
No takes yet. Share an insight, caveat, or question.
Elhaddad et al. (2022) studied this question.