Key result
Cardiac implantable device infections (CIEDI) were associated with higher in-hospital mortality after lead extraction compared to non-infectious indications (2.27% vs. 0.49%; P<0.0001).
Why the study?
Cardiac implantable device infections have poor outcomes despite improvements in transvenous lead extraction procedures.
Does systemic versus local infection impact in-hospital outcomes in patients undergoing transvenous lead extraction for cardiac implantable device infections?
Observational (n=3,555)
Yes
Does systemic versus local infection impact in-hospital outcomes in patients undergoing transvenous lead extraction for cardiac implantable device infections?
Absolute Event Rate: 2.27% vs 0.49%
p-value: p=<0.0001
Systemic infection in patients undergoing transvenous lead extraction is associated with a significantly higher risk of in-hospital mortality compared to local infection or non-infectious indications.
CIEDI patients warrant heightened TLE vigilance; observational data leave open whether systemic cases arise de novo.
Background: Infections of cardiac implantable devices (CIEDI) have poor outcomes despite improvement in lead extraction (TLE) procedures. Methods: To explore the influence of CIEDI on the outcomes of TLE and the differences between patients with systemic (Sy) vs. local (Lo) CIEDI, we performed a sub-analysis of the EORP ELECTRa (European Lead Extraction ConTRolled) Registry. Results: Among 3555 patients enrolled by 73 centers in 19 Countries, the indication for TLE was CIEDI in 1850: 1170 with Lo-CIEDI and 680 with Sy-CIEDI. Patients with CIEDI had a worse in-hospital prognosis in terms of major complications (3.57% vs. 1.71%; p = 0.0007) and mortality (2.27% vs. 0.49%; p < 0.0001). Sy-CIEDI was an independent predictor of in-hospital death (H.R. 2.14; 95%CI 1.06−4.33. p = 0.0345). Patients with Sy-CIEDI more frequently had an initial CIED implant and a higher prevalence of comorbidities, while subjects with Lo-CIEDI had a higher prevalence of previous CIED procedures. Time from signs of CIEDI and TLE was longer for Lo-CIEDI despite a shorter pre-TLE antibiotic treatment. Conclusions: Patients with CIEDI have a worse in-hospital prognosis after TLE, especially for patients with Sy-CIEDI. These results raise the suspicion that in a relevant group of patients CIEDI can be systemic from the beginning without progression from Lo-CIEDI. Future research is needed to characterize this subgroup of patients.
No takes yet. Share an insight, caveat, or question.
Diemberger et al. (2022) conducted an observational in Cardiac implantable device infection (n=3,555). Cardiac implantable device infection (CIEDI) vs. Non-CIEDI indications for lead extraction was evaluated on In-hospital mortality (p=<0.0001). Cardiac implantable device infections (CIEDI) were associated with higher in-hospital mortality after lead extraction compared to non-infectious indications (2.27% vs. 0.49%; P<0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: