Any amplifier operated with a varying supply voltage is actually a three-port circuit, having two inputs and one output. When an amplifier is characterized as a three-port for dynamic supply voltage operation, three separate operating modes appear: linear L-mode and the two nonlinear modes C-mode and P-mode. Each of these modes, along with their relationships and differences, are identified, characterized, and discussed. Relations of these modes to the dynamic power supply transmitter techniques of envelope tracking and/or direct polar are presented. Measurements are reported that provide experimental verification for these amplifier operating modes.
No takes yet. Share an insight, caveat, or question.
Earl McCune (2014) studied this question.