Answers are grounded in this paper and cite their sources.
Upstream flow disturbances degrade ultrasonic transit-time flow measurement by introducing transit-time jitter along the acoustic path. This paper characterizes how butterfly valve closure angle affects the uncertainty of a dual-path transit-time sensor (DN250, water, 7.5D downstream) when a variable-speed pump maintains a constant flow rate. Eleven valve angles (0 to 81 degrees), a baseline, and an Asymmetric Swirl Generator were tested. Formal hypothesis testing showed that the linear blockage coefficient is not statistically significant at the 95% confidence level, yielding a reduced two-parameter model dominated by vortex shedding with sine-squared scaling of the valve angle. The saturation flow rate of (95 ± 9) m 3 /h remained constant across configurations, confirming bandwidth-limited uncertainty behavior governed by the sensor Nyquist-frequency limit. A transition near 63 degrees defines a practical operating limit of 60 degrees. The Asymmetric Swirl Generator produced approximately 15% higher turbulence than a fully open valve. The single experimental configuration and the two-point exponential region are discussed as constraints on generalizability.
No takes yet. Share an insight, caveat, or question.
Szewczyk et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: