Key result
Modified Allen's test is clearly positive in ~49% of patients undergoing cardiac catheterization.
Why the study?
What is the frequency of positive, moderately positive, and negative modified Allen's tests in patients undergoing cardiac catheterization?
Cross-Sectional (n=1,000)
What is the frequency of positive, moderately positive, and negative modified Allen's tests in patients undergoing cardiac catheterization?
Over a quarter of patients undergoing cardiac catheterization have a negative modified Allen's test (≥ 10 seconds), highlighting the variability in collateral hand circulation prior to potential radial access.
Answers are grounded in this paper and cite their sources.
Alerts to frequent negative Allen's tests before catheterization; hypothesis-generating for its role in guiding radial access decisions.
The modified Allen's test (A.T.) is used to prove the adequacy of the blood supply through the ulnar artery to the hand. The test is considered normal if, after compression of both the ulnar and radial arteries followed by repeated clenching of the fingers to squeeze out the blood, the normal or a slightly more pronounced red color of the palm of the hands returns within < 10 sec after release of only the ulnar artery. It is important to perform the test whenever intravascular access to the radial artery is planned. The objective of this study was to determine the percentage of patients presenting a clearly positive (< 5 sec), a moderately positive (between 5-9 sec), or a negative A.T. (10 sec and more), We performed an A.T. on 1,000 consecutive and different patients undergoing cardiac catheterization, on the right wrist, two times, each time by a different examinator trained in this test. An A.T. was performed on 1,000 patients:640 men, 360 women, mean age 62.3 yr (range 28-90 yr). In our population of patients, the relative percentages of a clearly positive (< 5 sec), moderately positive (between 5-9 sec), or negative modified Allen's test (10 sec and more) is 49%, 24%, and 27%, respectively.
No takes yet. Share an insight, caveat, or question.
Benit et al. (1996) conducted a cross-sectional in Patients undergoing cardiac catheterization (n=1,000). Modified Allen's test was evaluated on Frequency of a clearly positive (< 5 sec), moderately positive (5-9 sec), or negative (≥ 10 sec) modified Allen's test. Among 1,000 consecutive patients undergoing cardiac catheterization, the modified Allen's test was clearly positive in 49%, moderately positive in 24%, and negative in 27%.
Synapse has enriched 10 related papers. Consider them for comparative context: