Key result
Valve-in-valve TAVR with surgical true-ID ≤21mm is linked to ~16 mmHg higher 1-year mean gradients.
Why the study?
Although VIV-TAVR provides good initial outcomes, lacking long-term durability data hinders expansion to lower-risk patients.
Does VIV-TAVR provide durable hemodynamic improvement and survival in patients with failed aortic bioprostheses?
Observational (n=77)
Does VIV-TAVR provide durable hemodynamic improvement and survival in patients with failed aortic bioprostheses?
Absolute Event Rate: 29.2% vs 13%
p-value: p=0.004
While VIV-TAVR is safe and effective early on, steadily increasing transvalvular gradients over 3 years raise concerns about long-term durability, particularly in smaller surgical valves.
3-year VIV-TAVR hemodynamics support use in high-risk patients; leaves open durability questions for lower-risk expansion.
Background VIV-TAVR is established and provides good initial clinical and hemodynamic outcomes. Lacking long-term durability data baffle the expand to lower risk patients. For those purposes, the present study adds a hemodynamic 3-years follow-up. Methods A total of 77 patients underwent VIV-TAVR for failing aortic bioprosthesis during a 7-years period. Predominant mode of failure was stenosis in 87.0%. Patients had a mean age of 79.4±5.8 years and a mean logistic EuroSCORE of 30.8±15.7%. The STS-PROM averaged 5.79±2.63%. Clinical results and hemodynamic outcomes are reported for 30-days, 1-, 2- and 3-years. Completeness of follow-up was 100% with 44 patients at risk after 3-years. Follow-up ranged up to 7.1 years. Results Majority of the surgical valves were stented (94.8%) with a mean labeled size of 23.1±2.3mm and true-ID of 20.4±2.6mm. A true-ID ≤21mm had 58.4% of the patients. Self-expanding valves were implanted in 68.8% (mean labeled size 24.1±1.8mm) and balloon-expanded in 31.2% (mean size 24.1±1.8mm). No patient died intraoperatively. Hospital mortality was 1.3% and three-years survival 57.1%. All patients experienced an initial significant dPmean-reduction to 16.8±7.1mmHg. After 3-years mean dPmean raised to 26.0±12.2mmHg. This observation was independent from true-ID or type of TAVR-prosthesis. Patients with a true-ID ≤21mm had a higher initial (18.3±5.3mmHg vs. 14.9±7.1mmHg; p=0.005) and dPmean after 1-year (29.2±8.2mmHg vs. 13.0±6.7mmHg; p=0.004). There were no significant differences in survival. Conclusions VIV-TAVR is safe and effective in the early period. In surgical valves with a true-ID≤21mm inferior hemodynamic and survival outcomes must be expected. Nonetheless, also patients with larger true-ID’s showed steadily increasing transvalvular gradients. This raises concern about durability.
No takes yet. Share an insight, caveat, or question.
Wilbring et al. (2022) conducted an observational in Failing aortic bioprosthesis (n=77). Surgical valve true-ID ≤21mm vs. Surgical valve true-ID >21mm was evaluated on Mean transvalvular gradient (dPmean) at 1 year (p=0.004). Following valve-in-valve TAVR, a surgical valve true-ID ≤21mm was associated with significantly higher mean transvalvular gradients at 1 year compared to larger valves (29.2 vs 13.0 mmHg; p=0.004).