Key result
Temporary epicardial pacing wires go unused in ~74% of post-cardiac surgery patients while delaying hospital discharge.
Why the study?
Temporary epicardial pacing wires are placed following cardiac surgery, but international guidelines guiding best practice for wire insertion or removal are lacking.
What are the patterns of use, duration, and complications of temporary epicardial pacing wires after cardiac surgery?
Cross-Sectional (n=167)
What are the patterns of use, duration, and complications of temporary epicardial pacing wires after cardiac surgery?
Routine insertion of epicardial pacing wires after cardiac surgery is common but often unused, and restrictive removal policies can lead to unnecessary delays in hospital discharge.
Answers are grounded in this paper and cite their sources.
Questions routine epicardial wire insertion post-surgery; hypothesis-generating for selective strategies and guideline development.
BACKGROUND: Temporary epicardial pacing wires are inserted after cardiac surgery. However, there are no international guidelines on which to base best practice regarding wire insertion or removal. METHODS: Data were collected on patients following cardiopulmonary bypass and analysed in terms of use, duration of use and complications of pacing wires after surgery. RESULTS: Wires were inserted in 164 of the 167 patients. Most (74%) did not require pacing. Patients were categorised into those who had aortic valve replacement (AVR) (n=42) and those who did not (n=122). Of the AVR group, 26% (n=11) were pacemaker dependent after surgery and 10% (n=4) required permanent pacemakers. Most pacing wires were removed by day 4. The only noted complication was delayed discharge. CONCLUSION: Unused pacing wires are normally removed on day 4, but for 77 (47%) of patients they remained in place longer. Forty patients (24%) had delayed wire removal because of a policy of wire removal during business hours only. Of these 40 patients, 27 (17% of the 77 with delayed removal) had delayed discharge as a result of our wire removal policy.
No takes yet. Share an insight, caveat, or question.
Kiely et al. (2020) conducted a cross-sectional in Post-cardiac surgery (n=167). Temporary epicardial pacing wires was evaluated on Use, duration of use and complications of pacing wires. Temporary epicardial pacing wires were unused in 74% of post-cardiac surgery patients, while a policy of removing wires only during business hours led to delayed discharge for 27 patients.
Synapse has enriched 10 related papers. Consider them for comparative context: