Key result
Ultrasound-guided axillary vein puncture is linked to ~56% shorter guidewire insertion time versus alternative techniques.
Why the study?
Few studies on ultrasound-guided axillary vein puncture (UGVP) have included complex cardiac device implantations such as defibrillators, cardiac resynchronization therapy, and upgrade procedures.
Does ultrasound-guided axillary vein puncture reduce guidewire insertion time and complications compared to alternative techniques in patients undergoing complex cardiac device implantation?
Cohort (n=96)
Does ultrasound-guided axillary vein puncture reduce guidewire insertion time and complications compared to alternative techniques in patients undergoing complex cardiac device implantation?
Ultrasound-guided axillary vein puncture is a feasible, safe, and faster alternative to traditional cephalic or subclavian access for complex cardiac device implantations.
May expedite axillary access in complex device implants; hypothesis-generating for safety outcomes in randomized trials.
Background The axillary route use for cardiac devices implantation has recently expanded either with fluoroscopy or ultrasounds guidance. Few studies included defibrillators (ICD), cardiac resynchronization therapy (CRT) and upgrade procedures for ultrasound-guided axillary vein puncture (UGVP). Puropose To assess the feasibility/safety of UGVP for complex cardiac devices implantation including CRT/ICD. Methods Consecutive patients eligible for a pacemaker or ICD implantation were included. All procedures were performed by three operators (one experienced and two fellows). Guidewires insertion time (from lidocaïne administration), and complications were systematically studied. A group of patients implanted with alternative techniques was used for comparison (cephalic, subclavian). Results In 176 consecutive patients in whom UGVP was used, a total of 68 complex procedures were analyzed (74 ± 8 y, male 61 %) with 138 leads implanted including 42 ICD, 48 CRT and 16 upgrade procedures. A majority (83 %) was under anti-thrombotic therapy. UGVP was successful in 96.8 %. Mean insertion time for 1.78 guidewires per patient was 4.4 ± 4.4 min. Guidewires insertion time reached its plateau after 10 patients. One pocket hematoma (1.4 %) was drained during a mean follow-up of 12 ± 5 months. The control group included 28 patients (12 subclavian, 16 cephalic; 15 ICD, 18 CRT, 4 upgrade procedures), with a mean insertion time of 10 ± 8 min, for 1.95 guidewires per patient (p < 0.0005). Conclusion UGVP is feasible and safe even for complex device implantations including CRT/ICD and upgrade procedures.
No takes yet. Share an insight, caveat, or question.
Bun et al. (2020) conducted a cohort in Complex cardiac devices implantation (CRT/ICD) (n=96). Ultrasound-guided axillary vein puncture (UGVP) vs. Alternative techniques (cephalic, subclavian) was evaluated on Guidewires insertion time (p=<0.0005). Ultrasound-guided axillary vein puncture for complex cardiac device implantation significantly reduced mean guidewire insertion time compared to alternative techniques (4.4 vs 10 minutes; p<0.0005).