Why the study?
The study aimed to compare the safety, efficacy, and radiation exposure of ultrasound-guided axillary vein access with conventional access techniques for cardiac implantable electronic device implantation.
Does ultrasound-guided axillary vein puncture reduce radiation exposure and procedural time compared to conventional access techniques in patients undergoing cardiac device implantation?
Does ultrasound-guided axillary vein puncture reduce radiation exposure and procedural time compared to conventional access techniques in patients undergoing cardiac device implantation?
Ultrasound-guided axillary vein puncture is a safe and effective alternative to conventional fluoroscopy-guided access for cardiac device implantation, significantly reducing radiation exposure without prolonging procedural time.
Answers are grounded in this paper and cite their sources.
May support axillary access for CIED implantation; leaves open need for randomized confirmation.
Ultrasound-guided axillary vein access is an effective alternative to conventional subclavian and cephalic access for cardiac implantable electronic device implantation. The aim of this study was to compare the safety, efficacy, and radiation exposure data of the ultrasound-guided axillary approach with other conventional access techniques. The study population included 130 consecutive patients, stratified as 65 (64% male; median age, 79 years) in the study group and 65 (66% male; median age, 81 years) in the control group. We performed a retrospective not-randomized analysis by comparing ultrasound-guided axillary vein puncture with subclavian and cephalic approaches in order to test the effect on X-ray exposure, total procedure time, and complications. Significant differences were observed in terms of radiation exposure, including fluoroscopy time (median, 95 s [study group] vs. 193 s [control group]; P < .001), air kerma (median, 29 mGy [study group] vs. 55.7 mGy [control group]; P < .001), and dose-area product (median, 8219 mGy cm 2 [study group] vs. 16736 mGy cm 2 [control group]; P < .001). The median procedure time was 45 min in the study group but 50 min in the control group (P < .05). Complications occurred in 6 control group patients (1 urticaria contrast medium-related, 3 pneumothorax, 2 subclavian artery puncture) and 2 study group patients (2 axillary artery puncture). We conclude that the ultrasound-guided axillary venous approach is a fast, feasible, and safe technique for cardiac lead implantation. It allows a significant reduction in fluoroscopy time without prolonging the procedural time. This approach offers direct visualization of the vessel during the puncture, so it can be useful in patients who cannot receive contrast medium, those who require "difficult" thoracic approaches (emphysema, too much or too little fat tissue), or those on anticoagulant therapy.
No takes yet. Share an insight, caveat, or question.
Maffè et al. (2023) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: