Key result
Ultrasound-guided axillary access for CIED implantation had similar success to fluoroscopic landmarks but reduced median fluoroscopy time.
Why the study?
Axillary vein access with fluoroscopy may increase radiation exposure, and studies comparing ultrasound-guided axillary access with fluoroscopic landmarks for CIED implantation were lacking.
Does ultrasound-guided axillary access reduce radiation exposure compared to fluoroscopic landmarks in patients undergoing CIED implantation?
Observational (n=95)
Does ultrasound-guided axillary access reduce radiation exposure compared to fluoroscopic landmarks in patients undergoing CIED implantation?
Ultrasound-guided axillary vein access for CIED implantation significantly reduces radiation exposure without compromising success rate or increasing procedural time compared to fluoroscopic guidance.
Answers are grounded in this paper and cite their sources.
May reduce radiation exposure in CIED implantation; hypothesis-generating and should not yet change practice.
Background Axillary vein access (AVA) using fluoroscopic landmarks is an effective and safe approach for cardiac implantable electronic devices (CIEDs) implantation. However, it may result in a higher radiation exposure. Ultrasound‐guided axillary access (USAA) is an effective alternative technique to conventional subclavian access for CIEDs implantation. Studies comparing USAA and AVA using fluoroscopic landmarks are lacking. The purpose of this study was to compare the safety, efficacy, and radiation exposure data of the USAA approach with the AVA using fluoroscopic landmarks. Methods The study population included 95 consecutive patients (61% male, median age 78 years [71‐85 years]) referred for CIEDs implantation using AVA with fluoroscopic landmark (n = 46) or USAA (n = 49). Baseline characteristics and radiation exposure data (Air‐Kerma [mGy], DAP [Gy‐cm2], fluoroscopy time [seconds], and X‐rays emission time [seconds]) were compared according to the technique used for the AVA. Results Axillary vein was successfully accessed in 45 of 49 (92%) patients using ultrasound and in 42 of 46 (91%) patients using fluoroscopic landmarks (P = 1.00). Air‐Kerma, DAP, fluoroscopy time, and X‐rays emission time were shorter for USAA group compared with AVA using fluoroscopic landmarks (11 mGy [8‐20] vs 37 mGy [24‐81], P < .00001; 3 Gy‐cm2 [2‐5] vs 10 Gy‐cm2 [6‐16], P < .00001; 97 seconds [62‐163] vs 271 seconds [185‐365], P < .00001; and 7 seconds [4‐10] vs 21 seconds [13‐39], P < .00001). There were no significant differences between the two groups in median implant procedure time (P = .55). We did not encounter any acute or long‐term complications in both groups. Conclusions Ultrasound‐guided axillary vein cannulation for CIEDs implantation is a feasible and safe alternative approach and offers a significant reduction in fluoroscopy times without increasing procedural time.
No takes yet. Share an insight, caveat, or question.
Migliore et al. (2020) conducted an observational in Cardiac implantable electronic device (CIED) implantation (n=95). Ultrasound-guided axillary access vs. Axillary vein access using fluoroscopic landmarks was evaluated on Successful axillary vein access (p=1.00). Ultrasound-guided axillary access for CIED implantation had similar success to fluoroscopic landmarks but reduced median fluoroscopy time.
Synapse has enriched 10 related papers. Consider them for comparative context: