Key result
MRI overestimates AVA by ~0.41 cm2 vs catheterization, showing only fair agreement for severe AS.
Why the study?
Does magnetic resonance imaging accurately assess aortic valve area compared to cardiac catheterization in patients with suspected severe aortic stenosis?
Cross-Sectional (n=34)
Single-blind
No
Does magnetic resonance imaging accurately assess aortic valve area compared to cardiac catheterization in patients with suspected severe aortic stenosis?
MRI and cardiac catheterization show low agreement in assessing aortic valve area in patients with suspected severe aortic stenosis, suggesting they may not be directly interchangeable.
Answers are grounded in this paper and cite their sources.
MRI should not yet be used interchangeably with catheterization for aortic valve area; leaves open validation of MRI-specific thresholds in severe aortic stenosis.
OBJECTIVE: Magnetic resonance imaging (MRI) is a novel technique used in the assessment of aortic stenosis. The aim of the study was to compare MRI and cardiac catheterization (CAT) that is still considered to be a "golden standard" in this indication. METHODS: Thirty-four patients referred to CAT for the evaluation of aortic stenosis were enrolled into the study. CAT was performed according to the standardized protocol. Cardiac output was measured by thermodilution and mean aortic gradient was determined using simultaneous blood pressure measurement in aorta and left ventricle. MRI was performed within the period of 3 weeks after CAT. True FISP sequence with retrospective ECG gating was used for the imaging of the aortic valve orifice. Planimetry of the aortic valve area (AVA) was performed at the time of maximal opening of the valve during systole. RESULTS: MRI enabled the measurement of AVA in all patients enrolled. Mean AVA defined by CAT and MRI were 0,97 (+/- 0,41) cm2 and 1,38 (+/- 0,55) cm2, respectively. The correlation between the evaluated methods was statistically significant (p=0,003), but not very strong (r=0,43). The comparison of both methods in the identification of the severe aortic stenosis was characterized by kappa value of 0,331. CONCLUSION: Our study shows low agreement between cardiac catheterization and magnetic resonance imaging in the assessment of aortic stenosis. However, MRI might have a role in the diagnostic algorithm in patients with suspected severe aortic stenosis and moderate mean aortic gradient or concomitant valvular insufficiency.
No takes yet. Share an insight, caveat, or question.
Solař et al. (2008) conducted a cross-sectional in Suspected severe aortic stenosis (n=34). Magnetic resonance imaging (MRI) vs. Cardiac catheterization (CAT) was evaluated on Mean aortic valve area (AVA) (Mean difference 0.41 cm2, p=<0.001). Magnetic resonance imaging overestimated aortic valve area compared to cardiac catheterization, showing only fair agreement for severe aortic stenosis.
Synapse has enriched 10 related papers. Consider them for comparative context: