Key result
Modified Dmax accurately determines anaerobic threshold heart rate versus continuous respiratory gas measurements.
Why the study?
Does the modified Dmax method accurately determine the heart rate at the anaerobic threshold compared to continuous respiratory gas measurements in healthy young girls?
Cross-Sectional (n=8)
Does the modified Dmax method accurately determine the heart rate at the anaerobic threshold compared to continuous respiratory gas measurements in healthy young girls?
The modified Dmax method is an accurate and reliable noninvasive alternative to continuous respiratory gas measurements for determining the anaerobic threshold in healthy young girls.
A wide variety of diagnostic techniques can be found in the literature for anaerobic threshold (AT) assessment.The aim of this study was to investigate if the heart rate (HR) at the modified D max method (Mod-D max ) using parallel straight line slope (PSLS) mathematical model and the Narita target heart rate equation was comparable with the HR measured at the AT by the continuous respiratory gas measurements in healthy young girls.Eight (age 19.29±1.70 years) healthy young girls performed an exhaustive treadmill exercise test for determination of the HR at Mod-D max using PSLS model and Narita equation.The AT of the participants was also calculated by the continuous respiratory gas measurements according to the Craig method.There was no significant difference between the HR determined at the Mod-D max method and the HR measured at the AT by the continuous respiratory gas measurements (167±9.22 vs. 165.25±6.32b/min).Bland and Altman plots revealed a good agreement between the determined HR at Mod-D max and values of the HR measured at the AT by the continuous respiratory gas measurements (95% CI =-20 to+22.8b/min).According to the results, the Mod-D max using PSLS model and the Narita equation during the exhaustive treadmill exercise test is an accurate and reliable noninvasive alternative to the cumbersome, expensive, and time-consuming invasive methods.Therefore, the Mod-D max method can be used for the determination of AT in healthy young girls.
No takes yet. Share an insight, caveat, or question.
Siahkouhian et al. (2012) conducted a cross-sectional in Healthy (n=8). Modified Dmax method (Mod-D max) using PSLS model and Narita equation vs. Continuous respiratory gas measurements (Craig method) was evaluated on Heart rate at the anaerobic threshold (95% CI -20 to +22.8). The modified Dmax method accurately determined heart rate at the anaerobic threshold compared to continuous respiratory gas measurements (167 vs 165.25 b/min; 95% CI -20 to +22.8).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: