Key result
Four non-invasive indices for determining anaerobic threshold significantly correlated with the invasive blood lactate method, with the Conconi threshold being the most adequate.
Why the study?
Do non-invasive indices accurately estimate the anaerobic threshold compared to invasive blood lactate measurements in adult male rowers?
Observational (n=22)
Do non-invasive indices accurately estimate the anaerobic threshold compared to invasive blood lactate measurements in adult male rowers?
Answers are grounded in this paper and cite their sources.
Non-invasive indices, particularly the Conconi threshold based on heart rate deflection, are comparable to invasive blood lactate measurements for estimating anaerobic threshold in elite rowers.
This study compared four common non-invasive indices with an invasive index for determining the anaerobic threshold (AT) in 22 adult male rowers using a Concept2 rowing ergometer. A criterion-standard progressive incremental test (invasive method) measured blood lactate concentrations to determine the 4 mmol/l threshold (La4-AT) and Dmax AT (Dm-AT). This was compared with three indices obtained by analysis of respiratory gases and one that was based on the heart rate (HR) deflection point (HRDP) all of which used the Conconi test (non-invasive methods). In the Conconi test, the HRDP was determined whilst continuously increasing the power output (PO) by 25 W/min and measuring respiratory gases and HR. The La4-AT and Dm-AT values differed slightly with respect to oxygen uptake, PO and HR however, AT values significantly correlated with each other and with the four non-invasive methods. In conclusion, the non-invasive indices were comparable with the invasive index and could, therefore, be used in the assessment of AT during rowing ergometer use. In this population of elite rowers, Conconi threshold (Con-AT), based on the measurement of HRDP tended to be the most adequate way of estimating AT for training regulation purposes.
No takes yet. Share an insight, caveat, or question.
Erdoğan et al. (2010) conducted an observational in Elite rowers (n=22). Non-invasive indices (respiratory gases and heart rate deflection point) vs. Invasive index (blood lactate concentrations) was evaluated on Anaerobic threshold (AT) estimation. Four non-invasive indices for determining anaerobic threshold significantly correlated with the invasive blood lactate method, with the Conconi threshold being the most adequate.
Synapse has enriched 10 related papers. Consider them for comparative context: