Key result
A high-profile TAVI prosthesis prevented sufficient aortic cross-clamping during subsequent minimally invasive mitral valve surgery, leading to procedural adjustments and extended ICU recovery.
Why the study?
When traditional double-valve surgery poses prohibitive risks in complex aorto-mitral pathologies, a staged approach of TAVI followed by endoscopic minimally invasive mitral valve surgery may serve as an alternative.
Case Report (n=1)
In staged TAVI and minimally invasive mitral valve surgery, high-profile TAVI prostheses can obstruct aortic cross-clamping, highlighting the need for strategic prosthesis selection.
Answers are grounded in this paper and cite their sources.
May complicate staged mitral surgery after TAVI; leaves open optimal prosthesis selection criteria.
BACKGROUND: In high-risk patients with complex aorto-mitral pathologies, surgical planning must carefully consider both current and future procedural needs. When traditional double-valve surgery poses prohibitive risks, a staged approach (initial transcatheter aortic valve implantation [TAVI]) followed by endoscopic minimally invasive mitral valve surgery (MIC-MVS) can be an alternative. CASE HISTORY: A 65-year-old female patient with severe aortic stenosis and mitral stenosis underwent TAVI. Minimally invasive mitral valve surgery was planned 6 weeks later. During surgery, the high-profile TAVI prosthesis prevented sufficient aortic cross-clamping, leading to procedural adjustments and an extended intensive care unit recovery. DISCUSSION: This case emphasizes the importance of careful prosthesis selection in staged procedures. The complication of an obstructed aortic cross-clamp due to high-implanted, high-profile transcatheter prosthesis illustrates how prosthesis choice can significantly affect subsequent surgeries. Interdisciplinary collaboration between surgeons and cardiologists is essential to anticipate such issues and ensure optimal patient outcomes.
No takes yet. Share an insight, caveat, or question.
Polat et al. (2025) conducted a case report in severe aortic stenosis and mitral stenosis (n=1). Staged TAVI and minimally invasive mitral valve surgery was evaluated. A high-profile TAVI prosthesis prevented sufficient aortic cross-clamping during subsequent minimally invasive mitral valve surgery, leading to procedural adjustments and extended ICU recovery.