The oxidative dissolution of uranium(IV) dioxide powder at room temperature in aqueous carbonate media has been investigated. Kinetic studies evaluating the efficacy of various oxidants, including K 2 S 2 O 8, NaOCl, and H 2 O 2, for dissolving UO 2 in alkaline solution have been performed, with H 2 O 2 exhibiting the most rapid initial dissolution at 0.1 M oxidant concentrations. This result is due in part to the ability of peroxide to act as both an oxidant and a ligand under alkaline conditions. A spectrophotometric titration was used to confirm peroxide coordination to the U(VI) metal center. The disappearance of characteristic absorbance maxima associated with UO 2 (CO 3 ) 3 4- (e.g., 448.5 nm) and a subsequent change in solution coloration upon titration with hydrogen peroxide indicated a change in speciation. Optimization of the hydrogen peroxide concentration indicated that the initial rate of uranium oxidation increased with increasing peroxide concentration, with a maximum reaction rate estimated at about 0.9 M peroxide. In addition, the effects of both the carbonate countercation and the carbonate concentration were also studied. It was determined that for 40 mg UO 2 0.5 M Na 2 CO 3 was the most propitious choice, exhibiting both a high initial dissolution rate and the highest UO 2 dissolution capacity among the systems studied.
No takes yet. Share an insight, caveat, or question.
Peper et al. (2004) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: