Key result
Implantation in a low-volume centre was associated with a significantly higher 3-year mortality compared to high-volume centres (16.3% vs 11.4%, adjusted HR 1.300), partly confounded by socio-economic factors.
Why the study?
Unexplained major differences in 3-year mortality after ICD implantation exist in Belgium, and centre volume and socio-economic differences might affect post-implantation survival.
Does ICD implantation at low-volume centres compared to high-volume centres affect 3-year mortality in patients receiving a first ICD?
Cohort (n=9,647)
Yes
Does ICD implantation at low-volume centres compared to high-volume centres affect 3-year mortality in patients receiving a first ICD?
Answers are grounded in this paper and cite their sources.
Low-volume centres for ICD implantation are associated with higher 3-year mortality compared to high-volume centres, which may be driven by differences in patient characteristics and socio-economic factors rather than procedural complications alone.
Background The implantable cardioverter-defibrillator (ICD) remains the cornerstone in the prevention of sudden cardiac death. Cost-effectiveness depends on survival after implantation. In Belgium there are unexplained major differences in 3-year mortality after ICD implantation. Centre volume and socio-economic differences might affect survival after implantation.Methods In total, 9647 patients underwent a first ICD implantation between February 2010 and 2016 in Belgium and were retrospectively compared for demographics, 30-day and 3-year mortality. Chi-squared and Mann-Whitney U tests were used to determine differences across centre volume.Results Low-volume centres treated patients with different characteristics and implanted more patients with ischaemic heart disease (50.2 vs 47.9%, p = 0.002), in primary prevention (66.7 vs 62.0%, p < 0.001) and with overall more comorbidities. Kaplan-Meier survival analysis showed a significant higher 3-year mortality in low-volume centres (16.3 vs 11.4%, p < 0.001). After adjudication with a multivariable Cox model, centre volume remained an independent predictor of 3-year mortality (low volume HR 1.300 [95% CI 1.124–1.504]. However similar 30-day mortality (0.6% in low vs 0.5% in high volume centres, p = 0.393) suggests that implantation related determinants alone are insufficient to explain the long-term survival difference. Socio-economic factors like regional average income (wealth) and overall survival (health) also were associated with the survival difference between low- and high-volume centres.Conclusions There exist large survival differences after ICD implantation between implanting centres in Belgium that cannot only be explained by a volume–outcome effect. Centres size and characteristics are inhomogeneous and vary according to different socio-economic variables. Some of these variables are also significantly associated with survival and warrant further investigation.
No takes yet. Share an insight, caveat, or question.
Ingelaere et al. (2025) conducted a cohort in Patients undergoing first ICD implantation (n=9,647). Implantation in a low-volume centre vs. Implantation in a high-volume centre was evaluated on 3-year mortality (HR 1.300, 95% CI 1.124-1.504, p=<0.001). Implantation in a low-volume centre was associated with a significantly higher 3-year mortality compared to high-volume centres (16.3% vs 11.4%, adjusted HR 1.300), partly confounded by socio-economic factors.