Why the study?
Both highly specialized heart centres and less specialized hospitals care for patients with implantable ICDs/CRT-Ds with remote monitoring, prompting investigation into potential treatment differences by centre implantation volume.
Does ICD implantation centre volume affect procedural parameters and outcomes in patients receiving an ICD with remote monitoring?
Does ICD implantation centre volume affect procedural parameters and outcomes in patients receiving an ICD with remote monitoring?
Higher ICD implantation volume is associated with shorter procedure and X-ray times but longer hospital stays, while remote monitoring effectively prevents inappropriate shocks across all volume groups.
Answers are grounded in this paper and cite their sources.
High-volume ICD centers' shorter procedures but longer stays should not yet alter referrals; leaves open net outcome benefits in remote-monitored patients.
BACKGROUND: Both highly specialized heart centres and less specialized hospitals care for patients with implantable ICDs/CRT-Ds with remote monitoring. OBJECTIVE: To investigate potential differences in patient treatment according to centre's ICD implantation volume. METHODS: Based on their 2012 ICD/CRT-D implantation volume, centres enrolled in the NORDIC ICD trial in Germany were assigned to one of three groups: high- (HV, n= 345), medium- (MV, n= 340) or low-volume (LV, n= 189). RESULTS: The HV-centres had a significant higher CRT-D proportion (41.7%; LV: 36.5%; MV: 23.2%; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001), significant shorter median procedure duration (49 min; MV: 58 min; LV: 60 min; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001) but significant longer median hospital stay (4 days; MV and LV: 3 days; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001) compared to MV- and LV-centres. The X-ray exposure was shorter in MV/HV-centres (MV: 3.4 min; HV: 3.6 min; LV: 5.5 min; P𝑔𝑙𝑜𝑏𝑎𝑙< 0.001). Only 3.5% (LV: 2.6%; HV: 3.5%; MV: 4.1%) patients received at least one delivered inappropriate shock and 2.5% (HV: 2.0%; LV: 2.6%; MV: 2.9%) patients had withheld inappropriate ICD shocks without subsequent inappropriate shock delivery within 24.5 months of median follow-up. CONCLUSION: Implantation volume-dependent differences were observed in the device selection, procedure duration and x-ray exposure duration. Remote monitoring in combination with adequate response pattern prevented imminent inappropriate shocks in all three groups.