Key result
The ESMD-NLM denoising method achieved a mean opinion score (MOS) error index <15 compared to >15 to 30 for VMD, EEMD, and MED methods on simulated noisy ECG signals.
Why the study?
Does the ESMD-NLM hybrid denoising method improve noise suppression and waveform detail preservation in simulated and real ECG signals compared to NLM, VMD, EEMD, and median filter methods?
Does the ESMD-NLM hybrid denoising method improve noise suppression and waveform detail preservation in simulated and real ECG signals compared to NLM, VMD, EEMD, and median filter methods?
Combining extreme-point symmetric mode decomposition with nonlocal means (ESMD-NLM) effectively suppresses high-frequency and muscle artifact noise in ECG recordings while preserving QRS complex amplitudes and waveform details better than existing denoising algorithms.
Answers are grounded in this paper and cite their sources.
ESMD-NLM outperforms benchmarks on simulated ECG denoising; leaves open clinical validation before practice adoption.
Electrocardiogram (ECG) signals contain a great deal of essential information which can be utilized by physicians for the diagnosis of heart diseases. Unfortunately, ECG signals are inevitably corrupted by noise which will severely affect the accuracy of cardiovascular disease diagnosis. Existing ECG signal denoising methods based on wavelet shrinkage, empirical mode decomposition and nonlocal means (NLM) cannot provide sufficient noise reduction or well-detailed preservation, especially with high noise corruption. To address this problem, we have proposed a hybrid ECG signal denoising scheme by combining extreme-point symmetric mode decomposition (ESMD) with NLM. In the proposed method, the noisy ECG signals will first be decomposed into several intrinsic mode functions (IMFs) and adaptive global mean using ESMD. Then, the first several IMFs will be filtered by the NLM method according to the frequency of IMFs while the QRS complex detected from these IMFs as the dominant feature of the ECG signal and the remaining IMFs will be left unprocessed. The denoised IMFs and unprocessed IMFs are combined to produce the final denoised ECG signals. Experiments on both simulated ECG signals and real ECG signals from the MIT-BIH database demonstrate that the proposed method can suppress noise in ECG signals effectively while preserving the details very well, and it outperforms several state-of-the-art ECG signal denoising methods in terms of signal-to-noise ratio (SNR), root mean squared error (RMSE), percent root mean square difference (PRD) and mean opinion score (MOS) error index.
No takes yet. Share an insight, caveat, or question.
Tian et al. (2016) studied Simulated and real ECG signal recordings corrupted by noise (n=9). Extreme-point symmetric mode decomposition combined with nonlocal means (ESMD-NLM) ECG signal denoising method vs. Nonlocal means (NLM), variational mode decomposition (VMD), ensemble empirical mode decomposition (EEMD), and median (MED) filter methods was evaluated on ECG signal restoration performance and visual quality (SNR, RMSE, PRD, and Mean Opinion Score [MOS] error index). The ESMD-NLM denoising method achieved a mean opinion score (MOS) error index <15 compared to >15 to 30 for VMD, EEMD, and MED methods on simulated noisy ECG signals.