Key result
ViV-TAVI in stentless bioprostheses yields ~50% device success vs stented valves despite comparable safety and efficacy.
Why the study?
Does ViV-TAVI in degenerated stentless bioprostheses have similar safety and efficacy compared to stented prostheses and native aortic valves?
Cohort (n=90)
Yes
Does ViV-TAVI in degenerated stentless bioprostheses have similar safety and efficacy compared to stented prostheses and native aortic valves?
Absolute Event Rate: 50% vs 76%
p-value: p=<0.001
Despite technical challenges and lower device success, ViV-TAVI in failed stentless aortic bioprostheses achieves similar early safety and long-term clinical efficacy compared to stented or native valves.
ViV-TAVI in stentless bioprostheses may remain feasible despite lower device success; leaves open questions on technique optimization pending prospective data.
OBJECTIVE: To compare the safety and efficacy of transcathether aortic valve-in-valve implantation (ViV-TAVI) in degenerated stentless bioprostheses with failed stented valves and degenerated native aortic valves. INTRODUCTION: Little is known about ViV-TAVI in degenerated stentless valves. METHODS: Out of 45 ViV-TAVI procedures reported in the POL-TAVI registry, 20 failed stentless valves were compared with 25 stented prostheses and propensity-matched with 45 native TAVI cases. The mean follow-up was 633 (95% confidence interval [CI], 471-795) days and Valve Academic Research Consortium-2 (VARC-2) definitions were applied. RESULTS: Patients with degenerated stentless valves were younger (65.6, CI 58-73.1 years vs 75.6, CI 72.2-78 [stented] vs 80.1, CI 78.7-81.6 y. [native], P < 0.001). Implantation was required later after surgery (11.5, CI 8-14.9 years) in the stentless cohort as compared with the stented one (6.2, CI 4.7-7.6 years, P = 0.006). ViV-TAVI in the stentless group was also associated with larger amount of contrast (211, CI 157-266 mL vs 135, CI 104-167 mL [stented] vs 132 (119-145) mL [native], P = 0.022). Using VARC-2 composite endpoints, ViV-TAVI in stentless prostheses was characterized by a lower device success (50% vs 76% in stented vs 88.9% in native TAVI, P < 0.001), but comparable early safety up to 30 days (73.7% vs 84% vs 81.8%, respectively, log-rank P = 0.667) and long-term clinical efficacy beyond 30 days (72.2% vs 72% vs 73.8%, respectively, log-rank P = 0.963). CONCLUSIONS: Despite technical challenges and a lower device success, ViV-TAVI in stentless aortic bioprostheses achieves similar safety, efficacy, and functional improvement as in stented or degenerated native valves.
No takes yet. Share an insight, caveat, or question.
Huczek et al. (2018) conducted a cohort in Degenerated stentless bioprostheses, failed stented valves, and degenerated native aortic valves (n=90). Transcatheter aortic valve-in-valve implantation (ViV-TAVI) in stentless bioprostheses vs. ViV-TAVI in stented prostheses and native TAVI was evaluated on VARC-2 device success (p=<0.001). ViV-TAVI in stentless bioprostheses had lower device success (50% vs 76% in stented vs 88.9% in native TAVI; P<0.001) but comparable early safety and long-term clinical efficacy.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: