Answers are grounded in this paper and cite their sources.
In this paper the Fault Tolerant (FT) vector controlled induction motor drive system is described and tested in various drive conditions. The influence of the rotor speed sensor faults on the properties of the analyzed drive are tested. Faults detection algorithms, based on different algorithms are developed and described. The results of the simulation carried out using the MATLAB/Sim Power System software are verified in experimental tests in Micro Lab Box DS 1202, in a wide range of motor speed changes. The proposed detection algorithms can be successfully applied in the Fault Tolerant Drive Systems (FTDS).
No takes yet. Share an insight, caveat, or question.
Klimkowski et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: