Key result
High-resolution infrared thermography during atrial fibrillation ablation detected esophageal thermal lesions in 18.75% of patients, all of whom experienced temperatures >50°C.
Why the study?
Does high-resolution infrared thermography characterize esophageal temperature dynamics and predict thermal injury during atrial fibrillation ablation?
Observational (n=16)
Single-blind
Does high-resolution infrared thermography characterize esophageal temperature dynamics and predict thermal injury during atrial fibrillation ablation?
High-resolution infrared thermography during AF ablation demonstrates that esophageal thermal injury occurs at temperatures >50°C and is associated with large spatiotemporal gradients.
Avoiding esophageal temperatures >50°C may reduce thermal injury risk during AF ablation; leaves open prospective validation of infrared thermography.
BACKGROUND: Catheter ablation for atrial fibrillation has potential to cause esophageal thermal injury. Esophageal temperature monitoring during ablation is commonly used; however, it has not eliminated thermal injuries, possibly because conventional sensors have poor spatial sampling and response characteristics. To enhance understanding of temperature dynamics that may underlie esophageal injury, we tested a high-resolution, intrabody, infrared thermography catheter to continuously image esophageal temperatures during ablation. METHODS AND RESULTS: Atrial fibrillation ablation patients were instrumented with a flexible, 9F infrared temperature catheter inserted nasally (n=8) or orally (n=8) into the esophagus adjacent to the left atrium. Ablation was performed while the infrared catheter continuously recorded surface temperatures from 7680 points per second circumferentially over a 6-cm length of esophagus. Physicians were blinded to temperature data. Endoscopy was performed within 24 hours to document esophageal injury. Thermal imaging showed that most patients (10/16) experienced ≥1 events where peak esophageal temperature was >40°C. Three patients experienced temperatures >50°C; and 1 experienced >60°C. Analysis of temperature data for each subject's maximum thermal event revealed high gradients (2.3±1.4°C/mm) and rates of change (1.5±1.3°C/s) with an average length of esophageal involvement of 11.0±5.4 mm. Endoscopy identified 3 distinct thermal lesions, all in patients with temperatures >50°C; all resolved within 2 weeks. CONCLUSIONS: Infrared thermography provided dynamic, high-resolution mapping of esophageal temperatures during cardiac ablation. Esophageal thermal injury occurred with temperatures >50°C and was associated with large spatiotemporal gradients. Additional studies are warranted to determine the relationships between thermal parameters and esophageal injury.
No takes yet. Share an insight, caveat, or question.
Daly et al. (2018) conducted an observational in Atrial fibrillation (n=16). High-resolution infrared thermography catheter was evaluated on Esophageal thermal injury identified by endoscopy. High-resolution infrared thermography during atrial fibrillation ablation detected esophageal thermal lesions in 18.75% of patients, all of whom experienced temperatures >50°C.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: