Key result
Intra-procedural ultrasound yields ~100% agreement with routine CXR for post-insertion subclavian CICC assessment.
Why the study?
Routine post-insertion CXR to confirm central venous catheter position is limited by radiation exposure, procedural delays, and its retrospective nature.
Does a standardized intra-procedural ultrasound protocol agree with routine post-insertion chest radiography for assessing catheter status in adult patients undergoing subclavian CICC placement?
Observational (n=868)
No
Does a standardized intra-procedural ultrasound protocol agree with routine post-insertion chest radiography for assessing catheter status in adult patients undergoing subclavian CICC placement?
A standardized intra-procedural ultrasound protocol showed 99.65% agreement with routine CXR for post-insertion assessment of subclavian CICCs, eliminating wait times and reducing costs.
Supports replacing CXR with intra-procedural ultrasound for subclavian CICC confirmation; leaves open randomized validation before practice change.
Routine post-insertion chest radiography (CXR) to confirm central venous catheter position is limited by its retrospective nature, radiation exposure, and procedural delays. This study evaluated the feasibility, safety, and efficiency of a standardized multimodal intra-procedural ultrasound protocol as an alternative to routine radiography in patients requiring subclavian centrally inserted central catheter (CICC) placement. This single-centre, prospective, observational agreement study included 868 adult patients undergoing placement of a CICC in a subclavian vein. A standardized intra-procedural ultrasound protocol integrating vascular tip navigation, the rapid atrial swirl sign (RASS) for tip location, and lung sliding assessment was performed. Routine post-insertion CXR served as the institutional reference comparator. The primary outcome was agreement between ultrasound and CXR on the final post-correction catheter status. Secondary outcomes included the final residual malposition rate, pneumothorax detection, turnaround time, cost-effectiveness, and environmental impact. Intra-procedural ultrasound identified initial catheter malposition in 51 cases (5.9%), all of which were corrected in real time. Ultrasound and CXR agreed on the final post-correction catheter status in 865 of 868 patients (99.65%; exact 95% confidence interval [CI] 98.99–99.93), and the final CXR-confirmed residual malposition rate was 0.12% (1/868; 95% CI 0.003–0.64). All three discordant cases were ultrasound-negative/CXR-positive. Exploratory operational screening indices for the initial ultrasound assessment were a sensitivity of 98.0% and a specificity of 99.9%. While ultrasound missed two cases of asymptomatic minimal pneumothorax (< 10%), neither required intervention. Implementation of the ultrasound protocol eliminated the 45-minute average wait time associated with radiography ( p < 0.001), avoided approximately 694.4 kg carbon dioxide equivalent emissions, and yielded net cost savings of CNY 97,180, with a benefit-cost ratio of 2.12. In this large prospective agreement study, a standardized four-zone intra-procedural ultrasound protocol showed near-complete agreement with routine CXR for final post-insertion assessment after subclavian CICC placement and, through real-time correction, reduced the residual malposition rate to 0.12%. These findings support an individualized, risk-stratified strategy in which routine post-insertion CXR may be waived in low-risk patients with normal ultrasound findings, rather than universal replacement of CXR. Multicentre external validation and formal diagnostic accuracy studies are warranted.
No takes yet. Share an insight, caveat, or question.
Wang et al. (2026) conducted an observational in Subclavian centrally inserted central catheter (CICC) placement (n=868). Standardized intra-procedural ultrasound protocol vs. Routine post-insertion chest radiography (CXR) was evaluated on Agreement between ultrasound and CXR on the final post-correction catheter status (95% CI 98.99-99.93). A standardized four-zone intra-procedural ultrasound protocol showed 99.65% agreement (95% CI 98.99-99.93) with routine CXR for final post-insertion assessment after subclavian CICC placement.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: