Experimental study demonstrates decoupled mechanical and thermal sensing using metal halide glass optical fibers, highlighting applications in wearable health monitoring.
Multifunctional optical fibers capable of independently resolving mechanical deformation and temperature are critical for next generation wearable and health‐monitoring technologies, yet their realization remains challenging. Here, we overcome this challenge by designing an organic–inorganic metal halide (OIMH) glass optical fiber. The fiber features a homogeneous luminescent core of (DOTG) 2 MnBr 4 (DOTG = 1,3‐di‐o‐tolylguanidinium) and a deliberately engineered waveguide with a low refractive index difference. This architecture provides exceptional mechanical compliance, allowing a bending radius of less than 1 mm, while simultaneously supporting independent signal transduction pathways. Mechanical stimuli (pressure, bending) are encoded through waveguide loss, while temperature is independently determined from the fluorescence lifetime of Mn 2+ ions. Consequently, simultaneous monitoring is achieved with high sensitivity (20.9% N −1 for pressure, 1.51% deg −1 for bending, and 0.793%°C −1 for temperature) without signal cross‐talk or complex algorithmic processing. We further demonstrate the fiber's utility in real‐time wearable motion tracking and wireless musculoskeletal sensing, highlighting the potential of OIMH fibers as a versatile material platform for advanced health monitoring.