Answers are grounded in this paper and cite their sources.
Multiscale simulation study demonstrates chain-oxygen disorder limits REBCO tape lifetime under 14 MeV neutron flux, suggesting oxygen-sublattice stability dictates fusion magnet durability.
The consumable centrepost of the Hyperion breeder carries the machine's peak field of 16.84 T inside its harshest neutron environment, so the irradiation lifetime of the centrepost REBCO conductor—not stress and not quench—sets the cadence at which the plant is opened and, through it, the fraction of the calendar available for power production. We pose the lifetime question as a coupled multiscale problem and solve it from first principles. Steady 14 MeV neutron transport supplies the fast-flux field and the primary-knock-on-atom (PKA) spectrum at the conductor; a displacement-cascade molecular-dynamics (MD) treatment with a machine-learned interatomic potential and an arc-dpa surviving-defect model converts that spectrum into Frenkel-pair statistics resolved by sublattice; a DFT+U treatment of the correlated Cu 3d/O 2p manifold fixes the chain-oxygen-vacancy energetics; and a hole-doping dome maps chain-oxygen loss onto the critical temperature and current. A Monte-Carlo composition screen over 4,000 samples spanning the material and irradiation-model uncertainties finds that an un-doped YBCO tape reaches its critical-current break-even fluence at =5.64×10^22 n m^-2—a factor of 1.48 above the artificial-pinning-center (APC) grade at 3.82×10^22 n m^-2—and the ordering un-doped > APC is robust in 100 % of the samples. The displacement analysis localises ≈78 % of surviving lattice displacements on the oxygen sublattice, naming chain-oxygen disorder as the dominant lifetime-limiting channel; and a converged DFT+U calculation of the pristine cell (E_tot=-2907.082 Ry) anchors the chain-oxygen-vacancy formation-energy series from a validated ground state. We report the governing equations, the numerical formulation, and the GPU high-performance-computing (HPC) campaign that produced the results, and we close with the one honest reconciliation the design must carry: the break-even-fluence ranking (radiation tolerance) is a distinct metric from the end-of-life in-field I_c margin at the full 16.84 T operating point, and the two are separated cleanly rather than conflated. The centrepost gains a physically grounded, conservative irradiation-lifetime basis whose engineering lever is oxygen-sublattice integrity, not pinning-center density. Key results (frozen anchors): Phistar = 5.64 ×10^22\; un = 5.64 ×10^22\; APC = 3.82 ×10^22\. Methods & codes: OpenMC, DAGMC. Related: Paper page · De-risking register · 3D model · Learn more about Kronos Part of the 2026 Kronos publication series; independently re-run and stamped in the Kronos de-risking register (DOI 10.5281/zenodo.22645689). All numerical values are frozen design-point anchors; see the register. Public research artifact. No proprietary, financial, or supply-chain information is included.
No takes yet. Share an insight, caveat, or question.
Ford et al. (2026) studied this question.