Answers are grounded in this paper and cite their sources.
Numerical simulation demonstrates feasible heat exhaust and passive decay-heat cooling in a compact spherical-tokamak breeder, highlighting viable thermal margins without active emergency power.
A compact spherical tokamak concentrates fusion power into a small volume, and the heat it makes must leave through the same small surfaces; whether the machine is buildable is decided at the heat path, not the plasma. We pose the coupled blanket-and-divertor thermal-hydraulic problem for the Hyperion breeder (frozen design point Q=3.076, =85.04 MW, I_p=9.66 MA, δ=-0.30, κ=2.0, B_0=8 T, R_0=1.20 m, aspect ratio A=2.5, centrepost peak field 16.84 T) as a set of governing equations—volumetric nuclear heating with energy multiplication, the coolant first law with Dittus–Boelter convection, first-wall conjugate conduction, the two-point divertor model closed by the Lengyel impurity-radiation integral, and a lumped passive decay-heat balance—and solve each numerically against frozen results in the Kronos De-Risking Register. The helium-cooled blanket recovers a total thermal power =95.2 MW (energy multiplication M_E=/=1.119), and a coolant mass flow of =91.7 kg s^-1 across a T=200 K rise removes it exactly: c_p T = 95.2 MW, closing the energy balance to the first digit. First-wall peak temperature is held inside the material envelope by a ≤ 6 mm coolant-channel gate; a self-cooled-lithium blanket variant runs at 516 ^C. Parallel power exhaust—an unmitigated =27.4 GW m^-2 giving a conventional attached target load of 1370 MW m^-2—is brought below the 10 MW m^-2 engineering limit by a stacked cascade (impurity seed, Super-X, double-null, snowflake) that drives the residual heat reaching the target from a seeded baseline of 6.4% to ≈ 0.5%, with a one-dimensional UEDGE scan resolving the target temperature through 14.45.31.05 eV and confirming that seeding is mandatory and sufficient for detachment. On loss of all active cooling the machine walks away passively: decay heat falls from 0.95 MW at 1 s to 95 kW at one day and passive rejection holds structural temperatures at or below 710 ^C. All numbers were produced by the NVIDIA GPU HPC campaign running OpenMC, SOLPS-ITER, UEDGE and SD1D on the frozen equilibrium. The heat path closes with margin at every stage and the safety case does not depend on powered cooling. Key results (frozen anchors): Pfus = 0.799 ×85.04; T = 91.7 ×5193; D_h = 2 d; rad = 99.3 %; rad = 94.2 %. Methods & codes: OpenMC, SOLPS-ITER, SOLPS, EIRENE, DAGMC, ENDF/B-VIII.0, Sauter, STEP, R2S. Live verification: 4 gate validator(s) with live-recompute cards (4 reproduced). See the Verification section and data/verification.csv. Related: Paper page · De-risking register · 3D model · Learn more about Kronos Part of the 2026 Kronos publication series; independently re-run and stamped in the Kronos de-risking register (DOI 10.5281/zenodo.22645689). All numerical values are frozen design-point anchors; see the register. Public research artifact. No proprietary, financial, or supply-chain information is included.
No takes yet. Share an insight, caveat, or question.
Priyanca Ford (2026) studied this question.