Key result
The strain phase of the Valsalva maneuver decreased P wave parameters in 36 patients with paroxysmal atrial fibrillation, while increasing them in normal subjects.
Why the study?
Does the Valsalva maneuver improve P wave parameters on 12-lead surface ECG in patients with paroxysmal atrial fibrillation?
Observational (n=73)
Does the Valsalva maneuver improve P wave parameters on 12-lead surface ECG in patients with paroxysmal atrial fibrillation?
The strain phase of the Valsalva maneuver decreases P wave duration and amplitude parameters in patients with paroxysmal atrial fibrillation, bringing them closer to normal levels.
Answers are grounded in this paper and cite their sources.
Suggests autonomic modulation may transiently normalize atrial conduction in paroxysmal AF.
The previous studies relating to the effect of the Valsalva maneuver on P wave do not provide detailed information. In those studies, the parameters related to P wave duration during the release phase of the Valsalva maneuver were evaluated. The authors evaluated P wave amplitude as well as P wave duration during the strain phase of the Valsalva maneuver. Thirty-seven normal subjects and 36 patients with paroxysmal atrial fibrillation (PAF) were included in the study. Twelve-lead surface electrocardiography (ECG) was obtained from all the patients before and during the strain phase of the Valsalva maneuver. The authors evaluated the parameters related to both P wave duration and P wave amplitude. The highest P wave voltage was expressed as the P wave amplitude maximum (P amp max), the lowest P wave voltage as the P wave amplitude minimum (P amp min), and the P wave amplitude dispersion (P amp dispersion) as "the P amp max - the P amp min." Also, the maximum P wave duration was expressed as the P maximum (P max), the minimum P wave duration as the P minimum (P min), and the P wave dispersion as "the maximum P wave duration (P max) - the minimum P wave duration (P min)." All these parameters were measured before and during the strain phase of the Valsalva maneuver. P max, P dispersion, P amp max, and P amp dispersion were higher in patients with PAF compared to those of normal subjects before the Valsalva maneuver. In normal subjects, P max, P wave dispersion, P amp max, and P amp dispersion values were significantly higher in the strain phase of the Valsalva maneuver than before (p<0.01, p<0.01, p<0.05, and p<0.05, respectively). In the patients with PAF, P max, P wave dispersion, P amp max, and P amp dispersion values were significantly lower during the strain phase of the Valsalva maneuver than before. In conclusion, in the patients with PAF, P wave parameters were decreased during the strain phase of the Valsalva maneuver, approaching to the normal levels.
No takes yet. Share an insight, caveat, or question.
Altunkeser et al. (2002) conducted an observational in Paroxysmal atrial fibrillation (n=73). Valsalva maneuver (strain phase) vs. Before Valsalva maneuver was evaluated on P wave duration and amplitude parameters (P max, P dispersion, P amp max, P amp dispersion). The strain phase of the Valsalva maneuver decreased P wave parameters in 36 patients with paroxysmal atrial fibrillation, while increasing them in normal subjects.
Synapse has enriched 10 related papers. Consider them for comparative context: